GB-2
Appropriate
PPE
(Personal Protective Equipment)
must be
worn whenever servicing the units
Warning
The unit must be installed and maintained by qualified, experienced technicians. Follow the operating
precautions to the letter when carrying out on the unit. Labels have been placed on the unit to remind you
of the safety instructions. As a general rule, follow all applicable safety regulations and standards.
1 - RECEIPT
Each air conditioner has a number plate bearing an identification number. This number must be included in
all correspondence.
In accordance with Article 133-3 of the French Code of Commerce, the recipient is entirely responsible for
checking the condition of the goods received.
In the event of missing items, the customer must provide the exact number of parcels delivered.
Any damaged or missing items must be specified on the delivery note in the presence of the driver before
signing the delivery note.
These comments must be confirmed to the carrier by registered letter within three
business days.
The comments "conditional" and "pending unwrapping" shall have no value.
The client must unwrap the goods in the presence of the driver.
Claims must be made at the time of delivery and be described in detail.
Equipment storage
The cabinet must be stored in a dry, sealed area, away from moisture and frost. The temperature in this
area must not exceed 50°C.
Equipment warranty
The warranty is effective for a period of 12 months from the date the unit is first commissioned provided
said date occurs within three months of the invoice date.
It is effective for a period of 15 months from the unit invoice date in all other cases.
Note
: for more information, refer to the information on the CIAT warranty.
2 - HANDLING
The unit must be lifted using slings or a spreader beam or be carried by a pallet truck and all four corners of
the unit must be supported by wooden blocks. In all cases, the cabinet must be raised by its base. This
operation must be carried out by qualified personnel: refer to the information on the label affixed to the
equipment.
Important
: The unit must be handled with care and kept vertical.
If the unit is lifted using a spreader beam and slings, tubes must be inserted in the designated holes at the
bottom of the unit.
•
The unit is delivered with caps on the frame which can easily be removed during handling.
•
If the unit is to be lifted using a spreader beam and slings, first remove all the caps covering the holes
for the pipes on the lower section of the equipment, on the front and rear of the frame. (fig.1.1)
•
Regardless of the handling method used, when finished:
- remove the wooden support blocks,
- fit the covers on the frame's front and side sections. (fig.1.3)
Protect the panels during
handling
Tube or bar
Min. lifting capacity 500 kg
Remove before handling then put
back in place
CAUTION! INTERNAL PIPES
Side opposite
access side
Access side