Charge/Discharge Controller 69200-1 User’s Manual
3-20
Command
Parameter
Description
CCV: CV Charge
CCP: CP Charge
CCD: CC Discharge
CVD: CV Discharge
CPD: CP Discharge
Syntax: SOURce:MODe
Parameter: CCC
Return Value: None
Command
Parameter
Description
SOURce:MODe?
None
String. Query operation status.
Syntax: SOURce:MODe?
Parameter: None
Return Value: CCC
Command
Parameter
Description
MEAS:ALL?
None
Query all measurement values.
Syntax: MEAS:ALL?
Parameter: None
Return Value:
Parameter
Data Type
Description
Operation Status
Unsigned integer
0: Output OFF
1: CC Charge
2: CV Charge
3: CP Charge
4: CC Discharge
5: CV Discharge
6: CP Discharge
Time ID
unsigned long
Measurement time. Unit (10ms).
User Alarm
Unsigned integer
0: ok
B0: BCH
B1: BCL
B2: BVH
B3: BVL
B4: TEST_DEBUG_MODE(T_DEBUG)
Tester Status
unsigned long
Protection status.
B0 : OUT_OCP
B1 : OUT_OVP
B2 : BUS_OVP
B3 : BUS_UVP
B4 : BUS_RVS
B5 : BAT_OVP
B6 : BAT_UVP
B7 : BAT_OCP
B8 : BAT_OTP
B9 : BAT_RVS
B10 : SYS_OCP
B11 : SYS_OTP
B12 : SYS_FAN
B13 : OUT_RVS