Local Operation
3-5
Item
Value
unit
Remarks
Total Capacity
Ah
Forced stop when over
SOC_100%
Ah
Warning when over
SOC_0%
Ah
Warning when under
DCR
mOhm
Fixed value
SOC_100%
V
Warning when over
SOC_0%
V
Warning when under
OVP
V
Forced stop when over
UVP
V
Forced stop when over
SCPI command settings: (Select initial capacity)
1. CHANnel:SOURce 1
2. OUTPut:MODe? (Start from step 3 if 0 is returned (Manual Test), or go to step 5 directly.)
3. OUTPut:STATe OFF
4. OUTPut:MODe 1
5. BATTery:OUTPut OFF
6. BATTery:INITial 0
--------------------------------------
7. BATTery:INITial:CAP
----------------------------------
8. BATTery:OCP 13.00
------------------------------------
9. BATTery:ESR 40
----------------------------------------
10. BATTery:BCH 100.0
------------------------------------
11. BATTery:BCL 0.0
----------------------------------------
12. BATTery:BVH 60.0
--------------------------------------
13. BATTery:BVL 0.0
----------------------------------------
can be replaced with BATT:ALL
14. BATTery:VH 60.0
---------------------------------------
15. BATTery:VL 60.0
---------------------------------------
16. BATTery:EFFCHG 100.0
-------------------------------
17. BATTery:EFFDSG 100.0
-------------------------------
18. BATTery:BOH 100.0
------------------------------------
19. BATTery:BOL 0.0
---------------------------------------
20. BATTery:VOH 60.0
-------------------------------------
21. BATTery:VOLP 0.0
--------------------------------------
22. BATTery:OUTPut 1
23. MEAS:OPER?
---------------------------------------
24. MEAS:STATe?
---------------------------------------
25. MEAS:CURR?
---------------------------------------
26. MEAS:VOLT?
---------------------------------------
27. MEAS:POW?
----------------------------------------
can be replaced with MEAS:ALL
28. MEAS:TIME?
---------------------------------------
29. MEAS:TEMP?
---------------------------------------
30. MEAS:AH?
------------------------------------------
31. MEAS:KWH?
---------------------------------------
Summary of Contents for 69200-1
Page 1: ......
Page 2: ......
Page 3: ...Charge Discharge Controller 69200 1 User s Manual Version 1 3 April 2017...
Page 8: ...vi...
Page 12: ......
Page 14: ......
Page 20: ......
Page 70: ......
Page 78: ......
Page 80: ...Charge Discharge Controller 69200 1 User s Manual 5 2 please notify Chroma for calibration...
Page 82: ......
Page 84: ......