Remote Operation
8-13
Query Syntax
: [LOAD:]ABA?
Response Parameter: OFF|ON
Example
: ABA ON
[LOAD:]MODE
Description: This command selects the operating mode for AC/DC voltage input. The
electronic load can be programmed to operate for constant current, constant power, constant
resistance, constant voltage(DC mode only), RLC(AC mode only), RLC constant power(AC
mode only), RLC inrush current(AC mode only), Rectified(DC mode only). The query form
returns the load operating mode for AC voltage input mode.
Setting Syntax
: [LOAD:]MODE
Setting Parameter : 0 | CURR, 1 | POW, 2 | VOLT, 3 | RES
4 | RLC, 5 | RLCP, 6 | INRUSH, 7 | RECT
Query Syntax
: [LOAD:]MODE?
Response Parameter : CURR, POW, VOLT, RES, RLC, RLCPOW, INRUSH, RECT
Example
: MODE CURR
[LOAD:]SCIRcuit
Description: Activate or inactivate short-circuited simulation. (It is only operating in
CC/CP/CV/CR Mode.)
Setting Syntax
: [LOAD:]SCIRcuit
Setting Parameter : 0 | OFF, 1 | ON
Query Syntax
: [LOAD:]SCIRcuit?
Response Parameter : 0 | 1
Example
: SCIR ON
[LOAD:]PROTect?
Description: This command returns the status of electronic load.
Query Syntax
: [LOAD:]PROTect?
Response Parameter : <NR1>
Example
: PROT?
Mnemonic
Bit
Value
Bit Weight
Meaning
FE
0
1
Under frequency range or over frequency range.
UV
1
2
AC Mode voltage is lower than 45V, DC Mode voltage is
lower than 7.5V.
UV
2
4
OVP
3
8
AC Mode voltage is higher than 350V.
OVPP
4
16
Voltage overshooting, Vpeak is higher than 600V.
OCP
5
32
AC/DC Mode current is higher than 18A(63802), 36A(63803)
or 45A(63804).
OPP
6
64
AC/DC Mode power is higher than 1800W(63802),
3600W(63803) or 4500W (63804).
OTP
7
128
Over temperature protection
FANFAIL
8
256
Fan fail
LDF
9
512
Load fail
FREQ ERR
10
1024
Frequency occurred variation condition when loading.
PWRFAIL
11
2048
Input power fail
[LOAD:] PROTect:CLE
Description: This command resets status of electronic load.
Setting Syntax
: [LOAD:] PROTect:CLE