Programmable AC/DC Electronic Load 63800 Series Operation & Programming Manual
3-56
R s e t = 4 0 . 0 A = 1 0 0 A / m s = 1 0 0 A / m s
I p ( m a x ) = 1 0 0 . 0 A
2. Press
3
,
0
then press
ENTER
to change the value to “30.0”.
I s e t = 3 0 . 0 A = 1 0 0 A / m s = 1 0 0 A / m s
I p ( m a x ) = 1 0 0 . 0 A
3. Move the cursor by pressing (
◄
,
►
) to the command line of “ =”.
I s e t = 3 0 . 0 A = 1 0 0 A / m s = 1 0 0 A / m s
I p ( m a x ) = 1 0 0 . 0 A
4. Press
1
,
0
,
5
then press
ENTER
to change the value to “105”.
R s e t = 3 0 . 0 A = 1 0 5 A / m s = 1 0 0 A / m s
I p ( m a x ) = 1 0 0 . 0 A
5. Move the cursor by pressing (
◄
,
►
) to the command line of “ =”.
R s e t = 3 0 . 0 A = 1 0 5 A / m s = 1 0 0 A / m s
I p ( m a x ) = 1 0 0 . 0 A
6. Press
1
,
0
,
5
then press
ENTER
to change the value to “105”.
R s e t = 3 0 . 0 A = 1 0 5 A / m s = 1 0 5 A / m s
I p ( m a x ) = 1 0 0 . 0 A
7. Move the cursor by pressing (
◄
,
►
) to the command line of “I
p
(max)=”.
R s e t = 3 0 . 0 A = 1 0 5 A / m s = 1 0 5 A / m s
I p ( m a x ) = 1 0 0 . 0
8. Press
2
,
5
then press
ENTER
to change the value to “25.0”.
R s e t = 3 0 . 0 A = 1 0 5 A / m s = 1 0 5 A / m s
I p ( m a x ) = 2 5 . 0 A
9. After setting the parameter of the load, the
LOAD ON/OFF
key should be pressed to turn
on the load, so that the load can sink the current. (The detailed information please refer
section 3.4.5