Section 6: Specifications
6-4 Christie DS+60/DW30/Matrix 3000 User’s Manual
General
Voltage Range
100 – 240 VAC nominal
Line Frequency
50 Hz – 60 Hz nominal
Max. Inrush Current
68 A
Current Rating
Both lamps on - 8.4A @ 100V (typical),
3.5A @ 240V (typical)
One lamp on - 4.8A @ 100V (typical),
2.0A @ 240V (typical)
Power Consumption
Both lamps on - 840W nominal
One lamp on - 480W nominal
Type
OSRAM 300W P-VIP
Power
300 Watts
Operating Position
±
20 deg. tilt from horizontal plane
Warm up to full brightness
5 minutes
Lamp Life (typical)
1500 hours per lamp
Dimensions (L x W x H)
374mm x 510mm x 256mm
14.7” x 20.1” x 10.1”
Weight 36
lbs
CAN/CSA C22.2 No. 60950-00
ANSI/UL 60950 3
rd
Edition
EN60950, 2000 European Norm, Safety of Information Technology Equipment
China Compulsory Certificate (CCC)
FDA
Emissions
FCC Code of Federal Regulations, Title 47, Part 15, Conducted and Radiated
Emissions, Class A
EN55022 (CISPR 22) for Information Technology Equipment, Conducted and
Radiated, Class A
EN61000-3-2 Induced Harmonic Distortion
EN61000-3-3 Induced Voltage Fluctuations (Flicker)
Immunity
EN55024, specific to Information Technology Equipment (all parts), under which are:
EN61000-4-2 ESD,
EN61000-4-3 Radiated Immunity,
EN61000-4-4 Fast Transient/Burst Immunity
EN61000-4-5 Surge Immunity,
EN61000-4-6 Immunity to Conducted Disturbances,
EN61000-4-8 Magnetic Field Immunity,
EN61000-4-11 Voltage Dips, Short Interruptions and Voltage Variations Immunity
Power
Requirements
'
Lamps
'
Size and Weight
'
Safety
'
EMI
'