Section 4: Maintenance
User’s Manual 4-9
.
The two filters located at the front and
left side of the projector should be
replaced whenever the lamp is
replaced. If you are working in an
extremely dusty environment you may
want to replace the filters sooner. Use
the filters provided in the Christie
approved Lamp and Filter Kit for your
specific projector model.
1. TURN OFF THE PROJECTOR,
COOL and UNPLUG
Before removing or installing a filter, turn off the projector and allow it to cool for
5 minutes before unplugging.
2. REMOVE FILTER ACCESS PANELS
Loosen the captive screw(s) on the filter
access panels using a #1 Phillips
screwdriver. (Front access panel located to
the left of the lens – 1 screw. Left side
access panel – 3 screws. See Figure 4.6.)
3. REPLACE
FILTERS
Pull the old filters out of the projector and
discard. Do not reuse filters. Insert the new
filters with the wired side in. See Figure 4.7.
4. REPLACE
ACCESS
PANELS
Replace the two (2) filter access panels and
tighten the screws loosened in step 1.
Filter Replacement
'
Procedure
Figure 4.6. Remove Filter Access Panels
Figure 4.7. Replace Filters
Summary of Contents for DS+5K
Page 2: ...Downloaded From projector manual com Christie Manuals...
Page 6: ...Downloaded From projector manual com Christie Manuals...
Page 98: ...Downloaded From projector manual com Christie Manuals...
Page 110: ...Downloaded From projector manual com Christie Manuals...
Page 114: ...Downloaded From projector manual com Christie Manuals...
Page 128: ...Downloaded From projector manual com Christie Manuals...
Page 130: ...Downloaded From projector manual com Christie Manuals...
Page 148: ...Downloaded From projector manual com Christie Manuals...