Installing the lamp
Complete the following procedure to install the lamp.
Warning! If not avoided, the following could result in death or serious injury.
•
This procedure must be performed by Christie qualified technicians.
•
EXPLOSION HAZARD! Always wear protective safety clothing (gloves, jacket, face shield)
approved by the manufacturer whenever the lamp door is open or when handling the lamp. Any
local or federal specifications take precedence over Christie's protective clothing
recommendations.
•
Do not open the lamp door while the lamp is on.
•
EXPLOSION HAZARD! Allow sufficient time for the lamp to cool down before powering down the
product, disconnecting it from AC, and opening the lamp door.
•
EXPLOSION HAZARD! Lamps and bare bulbs, even when packaged, may explode if dropped or
mishandled.
1. Prepare the projector for service.
a) Turn off the lamp and projector.
b) Allow the projector to cool for a minimum of 15 minutes.
c) Disconnect the projector from AC power.
2. Put on your protective clothing, face shield, and gloves.
3. Insert the key in the lamp door lock, turn the key, and open the lamp door.
4. Loosen the two screws and open the lamp access door.
Installation and setup
CP2415-Xe Installation and Setup Guide
21
020-103584-02 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Summary of Contents for CP2415-Xe
Page 1: ...Installation and Setup Guide 020 103584 02 CP2415 Xe...
Page 48: ......