7. Check the screen each time an adjustment is made.
The right-side adjustments affect the top right and bottom left points on the screen.
8. Once both cross hairs are in focus, tighten the lock screw for the right boresight.
9. Repeat steps 5 to 8 for the left side.
10. Verify each corner of the screen is equally in focus.
If this is not the case, try adjusting vertical boresight.
Adjusting the top and bottom boresight
Learn how to adjust the top and bottom (vertical) boresight.
Warning! If not avoided, the following could result in death or serious injury.
•
This procedure must be performed by Christie qualified technicians.
Caution! If not avoided, the following could result in minor or moderate injury.
•
Do not look directly into the lens when the light source is on. The extremely high brightness can
cause permanent eye damage.
1. Remove the lens surround.
2. Display the Boresight test pattern.
3. Loosen the lock screw highlighted in the image below.
Adjusting the image
CP2415-Xe Installation and Setup Guide
40
020-103584-02 Rev. 1 (09-2022)
Copyright
©