Rotating the integrator rod
Whenever the integrator module is moved or replaced, rotate the integrator rod for proper focus and
full illumination of the three digital micromirror devices (DMDs).
Warning! If not avoided, the following could result in death or serious injury.
•
UV EXPOSURE! Protective UV safety glasses with side shields and protective safety clothing
approved by Christie must be worn when performing optical adjustments or servicing the
product.
1. Display a full white field test pattern.
2. Remove the top cover.
3. Put on a pair of heat resistant gloves and UV resistant glasses.
4. Open the integrator rod access door.
5. Loosen the two integrator rod screws.
6. If the image is not parallel to the screen, rotate the integrator rod.
7. If the edges of the image are not in focus, loosen the two screws on the end of the optical
housing and then move the handle attached to the lens backward and forward.
8. Verify no shadows exist on the screen.
If shadows appear, align the fold mirror (on page 44).
Adjusting the image
CP2415-Xe Installation and Setup Guide
43
020-103584-02 Rev. 1 (09-2022)