![Christie CA20-AC Installation And Setup Manual Download Page 43](http://html1.mh-extra.com/html/christie/ca20-ac/ca20-ac_installation-and-setup-manual_2603490043.webp)
8. If you proceeded automatically and the tablet is connected to the internet, CounterAct
Configure contacts Christie and registers the fixtures with the site from step 5.
The fixtures are registered and no further action is required.
If you get an error message, try again.
9. If you proceeded manually, CounterAct Configure presents a Register screen with a list of
fixtures in the right-side pane to be registered.
a) Click the first fixture.
A QR code is displayed in the left-side pane.
b) Scan the QR code with your smartphone.
The displayed website provides a registration code.
c) Enter the 11 digit registration code in the field beside the selected fixture.
d) Select Register.
e) For the remaining fixtures, repeat steps a to d.
Creating a schedule
Create a schedule to determine when during the day you want disinfection to occur.
1. From the homepage, select Schedule.
2. Select the plus sign (+)
3. To define a start time, from the Schedule page, select the arrow (>) to the right of the Start
time.
4. In the Select time dialog, scroll through the times to select the new start time.
5. Select OK.
6. To define an end time, repeat steps 4 to 6.
7. Enable or disable Stealth mode when disinfecting.
8. Select the room to apply the schedule to.
9. Select Save.
Verifying the optical power output
Before operating CounterAct with people other than trained operators in the room, ensure you validate
the installation height by measuring the optical power output.
1. Run all the fixtures in Disinfection mode.
2. Use a meter to measure the optical power output to validate acceptable power levels.
This step must be done to ensure the American Conference of Governmental Industrial
Hygienists (ACGIH) limit of 0.76uW/cm
2
(callout A in the Planning the installation height
diagram (on page 21)) is not exceeded.
•
Single-lamp mode—the fixture must be installed in a ceiling with a minimum height of 6.7
m (22 feet) to 8.5 m (28 feet).
•
Dual-lamp mode—the fixture must be installed in a ceiling with a minimum height of 8.5 m
(28 feet).