P00 Main frequency source setting
0
~
5 4
Set frequency inverter main frequency source
0: Keyboard digital setting
It could be set through P14 or
▲
、
▼
keys.
1: Analog signal 0
~
10V input (AVI)
Running frequency is set by external analog voltage signal
AVI(0.0
~
10.0V), related characteristics, please refer to the
description of P128
、
P129 and P130 parameters.
2: Analog signal 4
~
20mAinput (ACI)
Running frequency is set by external analog current signal
ACI(0.0
~
20.0mA), related characteristics, please refer to the
description of P131
、
P132 and P133 parameters.
3: Communication setting (RS-485)
Accept the frequency of upper computer or host machine setting
instruction through serial communication RS485 interface.
4: Keyboard potentiometer setting
Frequency is set by the potentiometer knob on the operation
keyboard, related characteristics, please refer to the description of
P160
、
P161 and P162 parameters.
5: UP/DW terminals increase by degrees and Decrease by
degrees setting
Initial value could be set through P111, frequency could be increased
and Decreased by degrees by external UP/DOWN terminal,
corresponding S2~S5 terminals should be selected and set P39
~
P42