SVF-MN Series Frequency Inverter Operation Manual Chapter 5 Function Parameter Detail
100
Set
value
Function
Description
completion
indication
within a phase
function is valid, each time after finish
a stage, selected port would output
valid signal, but only maintains 500ms,
and then recover
11
Mode run
completion
indication
When the executive program of the
drive revolve automatically and finish
all stages, this junction will be close,
but only maintain 500ms.
12
Freq. arrival
lower limit
When the output frequency of the drive
arrive upper limit frequency, the
selected output terminal outputs valid
signal.
13
Setting count
value arrival
When the drive execute external
counter, when count value is equal to
P96 set value, the selected output
terminal output valid signal.
14
Appoint count
value arrival
When the drive execute external
counter, and when the counter is equal
to P97 set value, the selected output
terminal output valid signal.
15
Pendulous
freq. upper and
lower limit
When parameter setting of pendulous
frequency run result in that the
pendulous freq. run freq. exceeds upper
and lower limit frequency limit,
valid signal (low level) is outputted.
16 S0
terminal
closed valid