P47 hot water frequency limitation
2~10
,
max frequency 20~100%
2~10= max frequency 20~100%
10
P48 AC heating AU mode highest temp
30~50
℃
30~50
℃
45
℃
P49 AC Heating AU mode offset
temperature
-10~10
℃
-10~10
℃
0
℃
P50 solenoid valve function parameters
0=G3 seasonal valve,
1=G3 solar valve
0= G3 is seasonal valve,
1=G3 is solar valve
0
P51 C4 Water pump type selection
0=AC Water pump,
1=EC Water pump
0=AC Water pump,
1=EC Water pump
1
P52 water pump working mode
0=Not stop, 1=stop after reaching
target temp
)
2=start 1 minute after
each stopping of 15 minutes
)
0=Not stop, 1=stop after reaching
target temp, 2=start 1 minute after
each stopping of 15 minutes
)
0
P53 EC Water pump C4 Minimum speed
40-80%
40-80% 40,
40
P54 C5 Water pump type selection
0=AC Water pump,
1=EC Water pump
0=AC Water pump,
1=EC Water pump
0
P55 DHW e-heater activated ambient temp
E1
-20~20
℃
-20~20
℃
0
℃
P56 Electric heating function
0=electric heating,
1=the second heat source
0=electric heating,
1=the second heat source
0
P57 AC e-heater activated ambient temp E2 -20~20
℃
-20~20
℃
0
℃
P58 2nd heat source starting air temp
-30~15
℃
-30~15
℃
-15
℃
P59 AC anti-freezing temperature
-15~5
℃
-15~5
℃
3
℃
P60 Virus killing interval days
7~99day
7~99 day
99
P61 Start virus killing time
1~24hour
1~24 hour
1
P62 Virus killing holding time
5~99minu
5~99 Min
5
P63 Target temperature of virus killing
55~80
℃
55~80
℃
55
℃
P64 AC water flow switch type selection
0=Water flow switch
1=flow meter
0=Normal Water flow switch
1=Water flow meter switch
1
P65 AC minimum water flow (Sets P5)
9-80L/m
9-80L/m
8
P68 air source heat pump FREECOOLING
function start ambient temp
-16~20
℃
-16~20
℃
5
℃
P69 FREECOOLING function additional
Temperature difference to start full free
cooling. (compressor stops)
3~15
℃
3~15
℃
5
℃
P71 Cooling Maximum set temperature
15~35
℃
15~35
℃
25
℃
P72 Heating maximum set temperature
25~55
℃
25~55
℃
55
℃
P73 DHW The highest set temperature
25~60
℃
25~60
℃
60
℃
NOTE: Your controller will show some parameters that are not listed here,
If they are not listed they are not applicable to the CX34
48
Summary of Contents for CX34
Page 4: ...Chiltrix Inc www chiltrix com CX34 Components 4 ...
Page 17: ...Chiltrix Inc www chiltrix com Electric Connections and Component Locator 17 ...
Page 18: ...Chiltrix Inc www chiltrix com CX34 System Wiring Diagram 18 ...
Page 24: ...Chiltrix Inc www chiltrix com G3 VALVE Seasonal Switch Valve G3 Ports 24 ...
Page 41: ...Chiltrix Inc www chiltrix com Standard Controller cont d Timer 4 Mode settings 41 ...