Structure
Definition
Minimum
Maximum
Programmed stop time : Period of
unloaded running before
stopping.
0 s
60 s
Power recovery time: time
beyond which the automatic
restarting shall not take place if it
is parameterized as Active.
10 s
3600 s
Automatic restart delay. Allows
restarts in cascade when several
compressors are working
together.
0 s
1200 s
Permissive start time: time during
which the compressor starter
protections (type permissive
START) are tested.
0 s
15 min
Communication time out: time
beyond which a communication
fault with other elements of a LAN
network is displayed as a fault.
10 s
60 s
Dryer status: allows activating/
deactivating the integrated dryer
management parameters.
Activated
Not activated
Drain time: opening period of the
condensates purge solenoid
valve.
1 s
25 s
Drain interval: interval between
two condensate purges.
1 min
60 min
Instruction book
2920 1804 00
67
Summary of Contents for CPF 175
Page 1: ...CPF 175 CPVS 175 Instruction book ...
Page 2: ......
Page 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Page 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Page 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Page 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Page 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Page 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Page 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Page 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Page 151: ......
Page 152: ...No 2920 1804 00 2012 08 ...