5.8
Taking out of operation
Disconnecting the compressor
At the end of the service life of the compressor, proceed as follows:
Step
Action
1
Stop the compressor and close the air outlet valve.
2
Switch off the voltage and disconnect the compressor from the mains.
3
Depressurize the compressor by opening the drain valve and loosening the oil filler plug
one turn.
For compressors equipped with electronic water drains, press the test buttons on top of
the electronic drains until the air system between the air receiver and the outlet valve is
fully depressurized.
4
Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
5
Drain the oil and condensate circuits.
On water-cooled compressors, drain the water circuits.
6
Disconnect the compressor condensate piping from the condensate drain net.
7
On water-cooled compressors, disconnect the cooling water pipes from the compressor.
8
Also read section Disposal of used material.
5.9
Use of air receiver
Instructions
Step
Action
1
This equipment can contain pressurized air and oil; be aware of its potential danger if used
improperly.
2
This equipment must only be used as compressed air/oil separator and must be operated
within the specified limits.
3
No alterations must be made to this equipment by welding, drilling, grinding or other
methods of mechanical working without written permission of the manufacturer. If there is
damage to a part under pressure from any cause, the complete part must be replaced.
4
For the oil separator vessel: original bolts have to be used after opening for inside
inspection. The bolts must be removed and fitted with the correct tool. The bolts must be
tightened with a torque of 185 Nm (+/- 45 Nm). Damaged bolts must not be re-used. O-
rings must be replaced.
5
The safety valve is designed in such a way that the pressure will not permanently exceed
the maximum allowable operating pressure of the vessel, except for short pressure surges
up to 1.1 times the design pressure.
6
Only use oil specified by the manufacturer.
7
Make sure the vessel is fully depressurized before opening the drain plug or fill plug.
Instruction book
2920 1804 00
117
Summary of Contents for CPF 175
Page 1: ...CPF 175 CPVS 175 Instruction book ...
Page 2: ......
Page 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Page 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Page 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Page 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Page 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Page 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Page 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Page 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Page 151: ......
Page 152: ...No 2920 1804 00 2012 08 ...