avoid affecting the stability of machine.
6. Alarm and Treatment
6.1
Title Explanation of Computer Alarm
No.
Title
Explanation
AL000
Alarm 1
Failure to use
AL001
Alarm 2
Failure to use
AL002
Temperature of the feeding pipe
does not meet the setting value
Actual temperature of the feeding pipe is lower than the
summation of temperature’s setting value and low
temperature deviation
AL003
Insufficient lubricant
Lubricant storage tank has a lower oil level
AL004
Drain valve of lubricator is plugged
Failure to use
AL005
Lubricant leakage or insufficient
lubricant
Lubricant pipe leakage or deficiency in slipping pressure
AL006
Oil pump motor is overload
To check the overload relay of oil pump motor
AL007
Mould adjusting motor is overload
To check the overload relay of mould adjusting motor
AL008
Rear safety door is unlocking
Lock the rear safety door and check the limit switch of
the rear safety door
AL009
Front safety door is unlocking
Lock the front safety door and check the limit switch of
the rear safety door
AL010
Mould adjustment is beyond the
minimum size
Mould thickness is beyond the minimum mould
thickness or check the frond limit switch of mould
adjustment
AL011
Mould adjustment is beyond the
maximum size
Mould thickness is beyond the maximum mould
thickness or check the front limit switch of mould
adjustment
AL019
Check the forward limit of the nozzle
Front limit switch of the nozzle is not trigged in automatic
operation
AL020
Protective cover of the nozzle is
unlocking
Protective cover is unlocking in injection
AL021
Nozzle hole meets foreign body
obstruction
While applying the nozzle obstructing alarm, injection
distance does not reach the second stage of the
injection or the nozzle hole meets foreign body
obstruction. Check the injection position setting or the
nozzle hole.
AL022
Insufficient plasticizing capacity or
feeding spilling
While applying the glue leakage alarm, injection
distance is beyond the position of injection feeding
spilling. Adjust the position setting of injection feeding
spilling or the final position of plasticizing.
AL023
No feeding in the hopper or the
hopper meets obstruction
Plasticizing time is beyond the setting cooling time in
automatic operation. Check whether meeting hopper
obstruction or excessive setting of plasticizing time.
Summary of Contents for Ai-02
Page 7: ...Ai 02 Operation Manual 4 Introduction on each Part of Computer s Panel 4 1 Computer s Panel 7...
Page 49: ...Time monitor interface 30...
Page 59: ...5 33 Help Help interface 40 Help interface 41 Help interface 42...
Page 110: ...6 4 Ai 02 circuit diagram 6 4 1 Ai 02 Input Connection Encoder Version...
Page 113: ...6 4 4 Ai 02 Motor Power Control Circuit SVP...
Page 115: ...6 4 6 Ai 02 Input Point Connection Diagram of Computer I O Board...
Page 116: ...6 4 7 Ai 02 Output Point Connection Diagram of Computer I O Board...
Page 117: ...6 4 8 Ai 02 extension I O board Connection Diagram...
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......