10
LT8227 (ISS 1)
•
Remove the 2 nuts located on the bottom of the glass frame.
Note
: when it is replaced ensure the glass is
central and that all the four studs pass through the slots in the glass frame.
•
While supporting the glass panel, remove the 2 nuts securing the sides of the glass frame, remove the glass
frame and slide it out gently.
•
Lay the glass panel down on a flat working surface on top of an old opened newspaper with the side to be
cleaned uppermost.
On stubborn stains (where the appliance has been used for a long period without glass panel being cleaned), use a
new
Brillo Pad
well wetted
with the Hob cleaner applied directly to it.
Ensure all the residues of the cleaner are removed with a damp cloth and the glass panel is completely dry before
fitting to the appliance.
SECTION FOUR Cleaning & Fuel Bed Laying Continued (user instructions)
Note: - If the fuel bed has not been placed correctly, causing the gas flame to contact the glass this may result in
glass staining that cannot be removed by cleaning.
Re-assemble in reverse order ensuring the seal is compressed evenly at the top and bottom
Re-fit the top canopy before re-fitting the trim and fret or fascia and before re-lighting.
CLEANING AND REPLACING Fuel Bed Parts
Important: -
Refer to the ‘Health & Safety Notice located on page 3 of this booklet
before cleaning or replacing
any refractory material.
Use only the Fuel Bed part provided NO OTHER FUEL BED PARTS SHOULD BE ADDED to the appliance
If any Fuel Bed Parts are broken then they must be replaced before the appliance is used.
The fuel bed parts are delicate and should be handled with great care.
The loose parts should be removed for cleaning. They can be brushed very gently with a soft brush to remove dust or
any deposits.
A vacuum cleaner may only be used after all the loose logs have been removed. Please ensure you have replacement
vermiculite and Embaglow available.
NOTE
: During operation some sooting will be evident on the fuel bed whether running on the high or low setting.
This may be reduced by running on the opposite setting for 15 minutes prior to switching the fire off i.e. If fire is