82001i-DF (EU)
82001i-DF (EU)
MAINTENANcE
SPEcIFIcATIONS
20
21
EN
Removing from Storage
If the generator has been improperly stored for a long period
of time with gasoline in the gasoline tank and/or carburetor, all
fuel must be drained and the carburetor must be thoroughly
cleaned. This process involves technically advanced tasks. For
assistance please call your nearest Champion distributor.
If the gasoline tank and carburetor were properly emptied of all
gasoline prior to the generator being stored, follow the below
steps when removing from storage.
1. Be sure the EZ Start dial is in the STOP position.
2. Add gasoline to the generator according to
3. Move the EZ Start dial to the START position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor
will need to be disassembled and cleaned or replaced. If
no gasoline leaks are found, turn the EZ Start dial to the
“STOP” position.
5. Check engine oil level and add clean, fresh oil if needed.
See
for proper oil type.
6. Check and clear air filter of any obstructions such as bugs
or cobwebs. If necessary, clean air filter according to
.
7. Start the generator according to
DANGER
Generator exhaust contains odorless and colorless carbon
monoxide gas.
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should
be followed:
–
When storing the generator make sure the EZ Start dial
is set to the “OFF” position.
SPEcIFIcATIONS
Generator Specifications
Generator Model
................................
82001i-DF (EU)
Start Type
................................................
Manual
Watts (Starting/Running)
...........................
2000/1600
Watts (LPG) (Starting/Running)
......................
1800/1440
AC Volts
..................................................
220/240
AC Amps @ 120V
.........................................
7/6.66
DC Volts
........................................................
12
DC Amps
.........................................................
8
Frequency
..................................................
50 Hz
Phase
.......................................................
Single
Gross Weight
..................................
57.5 lb. (26.1 kg)
Net Weight
......................................
48.7 lb. (22.1 kg)
Length
...........................................
20.5 in. (52 cm)
Width
.........................................
12.8 in. (32.5 cm)
Height
............................................
16.9 in. (43 cm)
Engine Specifications
Model
..............................................
YF149FD-L_G
Displacement
...............................................
80 cc
Type
................................................
4-Stroke OHV
Oil Specifications
DO NOT OVERFILL.
Type
............................................
*See chart below
Capacity
...........................................
0.4 qt. (0.4 L)
-20
0
20
40
60
Ambient temperature
Recommended Engine Oil Type
80
100
120
-28.9
°F
°C
-17.8 -6.7 4.4
15.6 26.7 37.8
48.9
10W-30
5W-30 Synthetic
10W-40
5W-30
NOTIcE
Weather will affect engine oil and engine performance.
Change the type of engine oil used based on weather
conditions to suit the engine needs.
Fuel Specifications
Use regular unleaded gasoline with a minimum octane rating of
85 and an ethanol content of 10% or less by volume. DO NOT
USE E15 or E85. DO NOT OVERFILL.
Gasoline Capacity
.................................
1.1 gal. (4.2 L)
Spark Plug Specifications
OEM Type
...........................................
NHSP E7RTC
Replacement Type
...................
NGK BPR7HS or equivalent
Gap
...............................
0.024-0.028 in. (0.6-0.7 mm)
Valve Specifications
Intake Clearance
.............................
0.004 in. (0.1 mm)
Exhaust Clearance
...........................
0.004 in. (0.1 mm)
NOTIcE
A technical bulletin regarding valve adjustment procedures
is available at www.championpowerequipment.com.
Temperature Specifications
Starting Temperature Range (°F/°C)
........
5 to 104/-15 to 40
NOTIcE
An important message about temperature:
Your product
is designed and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When your product is
needed it may be operated at temperatures ranging from
5°F (-15°C) to 122°F (50°C) for short periods of time. If
exposed to temperatures outside this range during storage,
it should be brought back within this range before operation.
In any event, the product must always be operated
outdoors, in a well-ventilated area and away from doors,
windows and vents.
Summary of Contents for 82001I-DF
Page 29: ...Page intentionally left blank Page intentionally left blank ...
Page 30: ......