SAfETy RULES

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas . Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death . If you start to feel dizzy or weak, get to fresh 
air immediately .

Operate generator outdoors only in a well ventilated 
area .
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle .
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings .
DANGER CARBON MONOXIDE: using a generator 
indoors

 CAN KILL YOU IN MINUTES .

dANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories . 
Traumatic amputation or severe laceration can result .

Keep hands and feet away from rotating parts .
Tie up long hair and remove jewelry .
Operate equipment with guards in place .
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught .

dANGER

Generator produces powerful voltage .

DO NOT touch bare wires or receptacles .

DO NOT use electrical cords that are worn, damaged 

or frayed .

DO NOT operate generator in wet weather .

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking .

Use approved transfer equipment to isolate generator 

from your electric utility and Notify your utility 

company before connecting your generator to your 

power system .

dANGER

Sparks can result in fire or electrical shock .

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug .

DO NOT check for spark with the plug removed .

Use only approved spark plug testers .

WARNING

Running engines produce heat . Severe burns can 

occur on contact . 

Combustible material can catch fire on contact .

DO NOT touch hot surfaces .

Avoid contact with hot exhaust gases .

Allow equipment to cool before touching .

Maintain at least three feet of clearance on all sides 

to ensure adequate cooling .

Maintain at least five feet of clearance from 

combustible materials .

WARNING

Medical and Life Support Uses .

In case of emergency, call 911 immediately .
NEVER use this product to power life support 
devices or life support appliances .
NEVER use this product to power medical devices 
or medical appliances .
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
euipment to live .
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency .

WARNING

The engine exhaust from this product contains 
chemicals known to the state of California to cause 
cancer, birth defects, or other reproductive harm .

WARNING

Read this manual thoroughly before operating your 
generator . Failure to follow instructions could result 
in serious injury or death .

WARNING

Summary of Contents for 41532

Page 1: ...CA 90670 USA 1 877 338 0999 www championpowerequipment com 9000 Starting Watts 7000 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual...

Page 2: ...the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Ca...

Page 3: ...ot Overload Generator 14 Capacity 14 Power Management 14 Operation at High Altitude 14 Maintenance and Storage 15 Engine Maintenance 15 Oil 15 Spark Plugs 15 Air Filter 15 Spark Arrester 16 Cleaning 1...

Page 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Page 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Page 6: ...s metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can...

Page 7: ...nd let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pump gas di...

Page 8: ...nt required 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to manually start the en...

Page 9: ...0 Amp Twist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 6 120 240 Volt AC 30 Amp Twist Lock Receptacl...

Page 10: ...function requires electrical current from the battery If the Ignition Switch is left in the ON position for extended periods several weeks the battery can be completely drained Moving the Ignition Sw...

Page 11: ...Wheel Kit 10 Wheel 2 Flange Bolt M10x120 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 2 Other Oil Funnel 1 Oil 1 16 qt 1...

Page 12: ...he following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generato...

Page 13: ...off and will stop when the oil level in the crankcase falls below the threshold level CAUTION Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the rec...

Page 14: ...el Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately below the top of the tank to allow for fuel expansion DO NOT pump gas directl...

Page 15: ...hen positioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrical...

Page 16: ...or a period of two 2 weeks or longer please see the Storage section for proper engine and fuel storage NOTE Recoil Start 1 Make certain the generator is on a flat level surface 2 Turn off all electric...

Page 17: ...evations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING...

Page 18: ...am element 3 Wash in liquid detergent and water Squeeze thoroughly dry in a clean cloth 4 Saturate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter...

Page 19: ...ster to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if it is damaged 6 Position...

Page 20: ...ded periods of time make sure that the Ignition Switch the Fuel Valve and the Battery Switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER A...

Page 21: ...erference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Page 22: ...36 37 38 39 40 41 42 43 44 45 41 46 47 48 40 41 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 29 27 86 87 88 89 90 91 92 93 94 95 96 7...

Page 23: ...9 GB96 10 Washer 10 1 60 ST07FD 02011200 THD Rotor Assembly 1 61 ST05FD 1151600 Air Guide 1 62 ST05FD 1152008 Plug A 1 63 ST05FD 1152009 Plug B 1 64 190FDE 2 GC1 Engine 1 65 ST182FD 1742203 UC Cover H...

Page 24: ...21 REV 41532 20120918 ENGLISH 41532 Specifications Engine Parts Diagram...

Page 25: ...RTC Spark plug 1 59 ST188F 1122000 G Ignition Coil 1 60 GB5789 FB6 29 Flange Bolt M6 29 4 61 ST188FD 1130003 CPE Carburetor Insulator Packing 1 Part Number Description Qty 62 ST188F 1134000 Carburetor...

Page 26: ...23 REV 41532 20120918 ENGLISH 41532 Wiring Diagram Specifications...

Page 27: ...Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected...

Page 28: ...r labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any ele...

Page 29: ...diagnosis parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EM...

Page 30: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Page 31: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Reviews: