![CG CDN40-012-65 Hardware Manual Download Page 25](http://html1.mh-extra.com/html/cg/cdn40-012-65/cdn40-012-65_hardware-manual_2585386025.webp)
Technical data
General data and operating conditions
CG Drives & Automation
21
Operation with normal duty at a 400 V mains
Type
Output currents [A] at switching frequency
2 kHz
4 kHz
8 kHz
16 kHz
I
rated2
I
aM2
I
rated4
I
aM4
I
rated8
I
aM8
I
rated16
I
aM16
CDN40-2P2-65
−
−
2.2
3.6
−
−
−
−
CDN40-3P8-65
−
−
3.8
6.4
−
−
−
−
CDN40-4P8-65
−
−
4.8
7.8
−
−
−
−
CDN40-7P0-65
−
−
7.0
11.2
−
−
−
−
CDN40-8P7-65
−
−
8.7
14.6
−
−
−
−
CDN40-012-65
−
−
11.6
19.0
−
−
−
−
CDN40-016-65
−
−
15.6
26.0
−
−
−
−
I
aNx
Rated value of continuous output current
I
aMx
Maximum output current (overload current)
•
Periodic load change of 3 s with I
aMx
and recovery time of 12 s
according to the tables under chapter 4.4
Fuses and cable
cross−sections
The data/recommendations for heavy duty operation on a rated mains voltage
400 V can be applied. (