Technical data
CG Drives & Automation
39
AS−Interface
Standards and application conditions
Feature
Value/designation
Type of protection
EN 60529
IP65
Climatic conditions
Storage (EN
60721−3−1)
1K3 (temperature: −30 °C ... +60
°C)
Operation (EN
60721−3−3)
3K3 (temperature: −30 °C ... +55
°C)
Transport (EN
60721−3−2)
2K3 (temperature: −30 °C ... +75
°C)
Insulation voltage to PE reference earth
EN
61800−5−1
U
AC
50.0 V
CANopen®
4.6.3
CANopen®
Feature
Value/designation
Communication
Communication profile
CANopen, DS301 V4.02
Medium
DIN ISO 11898
Baud rate
b
20 kbps
50 kbps
125 kbps
250 kbps
500 kbps
800 kbps
1000 kbps
Network topology
Line with 120 Ohm terminating resistor on both sides
Nodes
Slave
Multi master
Number of nodes
63
Number of logic process data channels
2 transmit PDOs and 2 receive PDOs (with 1 ... 8 bytes each)
Number of logic parameter
data channels
Max. 2 server SDO channels (with 1 ... 8 bytes)
Max. cable length
l
max
17 m with 1000 kbps
40 m with 800 kbps
110 m with 500 kbps
290 m with 250 kbps
630 m with 125 kbps
1500 m with 50 kbps
3900 m with 20 kbps
8000 m with 10 kbps
Rated voltage
U
rated
, DC
24.0 V
Summary of Contents for CDN40-012-65
Page 1: ...Emotron CDN Motor mounted AC drive 0 75 7 5 kW Hardware manual...
Page 2: ......
Page 70: ......