Technical data
Power terminals
34
CG Drives & Automation
Emotron CDN 0.75 ... 4 kW
Motor
Terminal data
Name
Power
Conductor
cross−section
[mm
2
]
[AWG]
Tightening torque
[Nm]
[lb−in]
X1
U, V, W
0.75 ... 2.2 kW
1 ... 4
18 ... 10
0.5
4.4
3.5 x 0.6
3.0 ... 4.0 kW
1 ... 6
18 ... 8
0.8
7.0
3.5 x 0.6
PE
0.75 ... 2.2 kW
1 ... 4
18 ... 10
1.7
16
8 x 1.2
3.0 ... 4.0 kW
1 ... 6
18 ... 8
1.7
16
8 x 1.2
Features
Name
Description
Rated value
X1
U, V, W
Motor phases
See rated data
Motor temperature monitoring
Terminal data
Name
Power
Conductor
cross−section
[mm
2
]
[AWG]
Tightening torque
[Nm]
[lb−in]
X1
T1, T2
0.75 ... 2.2 kW
1.5
16
0.5
4.4
3.5 x 0.6
2.0 ... 4.0 kW
1 ... 6
18 ... 8
0.8
7.0
3.5 x 0.6
Features
Name
Description
Rated value
X1
T1, T2
Motor temperature monitoring
See rated data
Danger! Hazardous electrical voltage.
•
T1 and T2 have DC−bus voltage potential
.
Danger!
Hazardous electrical voltage
Terminals T1, T2 are on
DC−bu
s voltage potential.
Possible consequences:
Death or severe injuries when touching the power terminals.
Protective measures:
Before working on the terminals, disconnect mains and wait for at
least 3 minutes.
Check whether the terminals are deenergized.