CFR 10416A Instruction Manual Download Page 21

CFR CASCADE

21

Ref # 

Part # 

Description

01 

72148A 

Nut, Cap 5/16-18 ZP

02 

X8025 

Wheel, Black

03 

7BF005 

Nut, Keps 5/16-18 Zinc

04 

72534A 

Tool Head Bracket, Right, P-20

05 

72394A 

Screw, Hex Self-Locking Flange

06 

72487A 

Shoulder Screw, Tool head

08 

72020A 

Screw, Self-tap PHMS Zinc

09 

72019A 

Bolt, 5/16-18 x 2-? Hex Tap Zinc

10 

7DT002 

Bolt, ?-20 x 5/8 Hex Tap Zinc

11 

72556A 

Weight Bar #2, 20”

12 

72484A 

Pin, Quick Release

13 

72506A 

Tool Head, 20”

14 

72555A 

Weight Bar #1, 20”

15 

72489A 

Stainless Steel Spray Tip

16 

72488A 

Brass Nozzle Body

17 

60400B 

Inline Strainer Assembly

18 

70101A 

Nipple, QD 1/8-1/8 M Brass

19 

SW139 

1/8 Street Elbow, 90 Degree

20 

72413A 

Valve, Check

21 

72557A 

Header, Cascade 20

22 

72437A 

Pad, Tool Head

23 

72541A 

Tool Head Bracket Sides, P-20

24 

X8218 

Washer, 5/16 SAE, Flat Zinc

25 

72486A 

Spacer, Toolhead Wheel

26 

72485A 

Tape, Toolhead Pad

27 

72533A 

Tool Head Bracket Left, P-20

Tool Head Assembly 

Ref # 

Part # 

Description

01 

72503A 

 Tank, Cascade 20

02 

72321A 

 Lid, Tank

03 

72323B 

 Gasket, Lid 43”

04 

72326A 

 Filter, Inlet

05 

72224B 

 Filter, Main

06 

71553A 

 E-Ring, Float Switch

07 

70343A 

 Switch Float 2 Pole

08 

71485A 

 Header Backflush Nozzle

09 

7DE016 

Nozzle H 1/8 VV CH SS

10 

70100A 

 Coupler QD 1/8F

11 

71495A 

 Pump Protection Filter

12 

72317B 

 Filter Mound 

13 

PC66  

 Fitting, Brass 1/8 NPTM

14 

PC25+ 

 Male/Male Barb.

15 

70079C 

 Hose, ? Wire Reinforced

16 

7DL008 

 Hose Clamp

17 

71897A 

 Gasket, Filter Mount

18 

72582A 

 Decal, Level Gauge

19 

72588A 

 Heat Shrink Tubing

20 

SW139+  Elbow, 1/8 Street.

21 

7CX001 

Nipple Hex 1/8

22 

71576A 

 Nipple QD 1/8 M SS

Ref # 

Part # 

Description

23 

7AF003 

 Plug, Counter Hex .

 

(Replaced by PC25 in ozone models)

24 

7DL003 

 Hose Clamp

25 

71817A 

 Hose, Braided

26 

PX31 

 Float Cage w/ Heavy Ball 

27 

72598A 

 Screw, Long, Phil Flat SS

28 

72589A 

 White Delrin Rod, ID, 7”

29 

PX33 

 Vacuum Tube

30 

PX63 

 Coupler, Plastic

31 * 

72575A 

 Label, Instruction 

 

72576A 

 Label, Instruction 

32 **  PX14A  

Dump Valve Gasket

33 

72476A 

 Fitting, Nylon Hose Barb

34 

7DL005 

 Clamp Worm Gear

35 

PAS37 

Drain Hose

36 

PAS36 

Expansion Plug Drain

37 

72543A 

 Label, Tank (Cascade 20)

38 

PX25 

 Fitting, Plastic, Hose Barb

39 

72384A 

 Hose, VAC Toolhead

41 

71920A 

 Ring Washer

42 

71644A 

 Screw, #10 x 1” Phil Pan

43 

72390A 

 Latch, Soft (Keeper)

Ref # 

Part # 

Description

44 

7DM004  Screw, 8-32 x 3/8 PHMS SS

45 * 

72384B 

 Hose, 20” 

46 * 

72409A 

 Inlet Fitting

47 

7BH004 

Screw, 10-32 x 3/8” Phil Pan 

48 

72173A 

 Spring Clip, Black Vinyl

49 

72615A 

Coupling, PVC, 1-1/2

50 

72616A 

Pipe, PVC

51***  7AT006 

Barb, 90° Elbow 1/4-1/8

52***  7AJ004 

Anchor Connector 1/8”

53***  71951A 

Orifice, Ozone Hose

54***  72115A 

Washer, 5/8 x 1-3/16  

 

Bonded Seal, Galvanized

55***  71785A 

Tee, 1/4” Hose Barb, Plastic

56***  71842A 

Reducer, Hose, 1/2” to 1/4”

57***  7GG003 

Hose A/S Braided

 

18-1/2” long from Reducer to Orifice

 

80” long from Orifice to Injector

* For self-propelled models only
** Use only one of the two in SP models.
*** For OZ models only.

Tank Assembly 

Summary of Contents for 10416A

Page 1: ...machine IMPORTANT SAFETY INSTRUCTIONS This manual is to ensure that the CFR Cascade is operated correctly All operators must read understand and practice the following safety instructions Models 1041...

Page 2: ...and chemicals All operators of the equipment must watch the video and read the manual before using the equipment Please complete and return the enclosed warranty card Parts and Service The Cascade is...

Page 3: ...ide plates with the two holes in the bracket The side of the plate with the foam should be placed on the inside of the bracket 2 Secure the side plates to the tool head bracket using two black hex scr...

Page 4: ...ter only runs when the pump is on Trigger Activates solution dispensing WARNING Do not turn power off on the machine by disconnecting the cord The electronic drive control will sense a power failure a...

Page 5: ...sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces 7 Turn off all controls before unplugging 8 Do not unplug by pulling on cord To unplug grasp the plug not the c...

Page 6: ...length of the room overlap ping each pass by a minimum of 2 inches If you have an irregularly shaped room Establish a path down the length of the room at the longest point overlapping each pass by a...

Page 7: ...damage 4 Close the machine fastening the latches 5 Reconnect the vacuum hose and replace the clear tank lid The Cascade utilizes multiple filters in the recycling of cleaning solution It is imperative...

Page 8: ...hould never be higher than the inlet filter Doing so will activate the automatic vac uum shut off and the machine will not operate CAUTION Water temperature above 140 F 60 C will cause the tank to buc...

Page 9: ...e the trigger for 30 seconds Adjust p s i from 0 to 400 if necessary Note For P20 OZ models turn on vacuum pump and ozone switches on and let machine run for 15 minutes before use P20 The easy to use...

Page 10: ...um motor flooding and machine damage 5 When cleaning monitor foam in the solution tank Residue left in the carpeting or upholstery from other cleaning methods may cause excessive foam to collect in th...

Page 11: ...ll power is off 2 Empty the tank Remove the drain hose from the clamp on the rear of the machine Remove the plug and hold hose over the drain area until tank is empty 3 Remove clear plastic lid 4 Remo...

Page 12: ...ockage 6 Open and clean the in line strainer filter and replace Disconnect the in line strainer filter by using the quick disconnect coupler Remove any debris from the strainer Keep o ring and threads...

Page 13: ...a tighter seal 3 Wipe tool with damp cloth and store with head up to prevent clogging of nozzle OPTIONAL ACCESSORIES Wand and Tool Usage Attaching Wand Hand Tool The Cascade self contained cleaning sy...

Page 14: ...the surface being cleaned to produce maximum cleaning effectiveness and minimum dry times Upholstery 1 Place tool on surface to be cleaned 2 Move pull and push tool at a rate of about one foot per se...

Page 15: ...s lower check for air leaks in the tank cover gasket and drain hose 4 Check pump performance occasionally against built in pressure gauge Pump running pressure should be 380 400 p s i When pumping flu...

Page 16: ...aking fittings inline strainer Re prime pump Rebuild pump or pressure regulator if necessary Water dripping from bottom Check machine for excess foaming Add CFR Defoam to tool hose of machine exhaust...

Page 17: ...PD8 Strain Relief NPT 21 72574A Switch Panel P 20 22 X8282 Bolt 20 x 1 Hex SS 23 X8008N Nut Lock Steel Conduit 24 72434A Jumper Tab 6 25 72432A Terminal Block 7 Positions 26 72361A Panel Motor Control...

Page 18: ...lon 1 8 x 1 8 43 7AG002 Bushing 1 8 NPT 44 71492A Solenoid 1 8 Orifice 71545A Solenoid 1 8 Orifice 230V 45 7CX002 Nipple Hex MPT 46 7AR013 Nipple NPT x 3 L SS 47 PX6 Female Quick Disonnect 48 72539A B...

Page 19: ...sher 5 8 SAE Flat Zinc 33 7DT001 Bolt 5 16 18 x 5 8 Hex Tap 34 7CR004 Washer 5 16 USS Flat 35 72551A Caster 4 x 2 Wheel 36 72590A Screw 8 x 5 8 Oval Head 37 72568A Wand Holder 38 7AR013 Nipple NPT x 3...

Page 20: ...CFR CASCADE 20 Tank Assembly...

Page 21: ...15 70079C Hose Wire Reinforced 16 7DL008 Hose Clamp 17 71897A Gasket Filter Mount 18 72582A Decal Level Gauge 19 72588A Heat Shrink Tubing 20 SW139 Elbow 1 8 Street 21 7CX001 Nipple Hex 1 8 22 71576A...

Page 22: ...distributor or autho rized service repair center per the warranty flat rate schedule Service labor will be paid for two years on all warranted polyethylene housings aluminum frames and chassis and one...

Page 23: ...CFR CASCADE 23...

Page 24: ...Cascade SERIES P20 INSTRUCTION MANUAl 3101 Wichita Court n Fort Worth TX 76140 n 800 533 2557 n www cfrcorp com Models 10416A P20 SP 10419A P20 10425A P20 OZ SP 10426A P20 OZ 10427A P20 OZ SP 230V 104...