CFR CASCADE
10
Operating the Cascade
2. The Cascade provides the ability to clean in 2
different modes.
Maintenance Mode
- Routine Maintenance is
performed on a regular basis to maintain the
appearance and the cleanliness of the carpeting.
• Adjust the p.s.i. to 200 and set the speed dial at 7.
Restorative Mode
- Restorative Cleaning allows
for the deepest cleaning of heavily soiled carpets or
high traffic areas.
• Adjust the p.s.i. to 400 and set the speed dial at 4.
3. Engage the trigger.
4. Begin cleaning by driving the machine forward in a
straight line. Overlap each pass by 2 inches.
CAUTION!
Monitor foam in the machine’s tank
through the clear plastic lid. Excessive foam may cause
vacuum motor flooding and machine damage.
5. When cleaning, monitor foam in the solution tank.
Residue left in the carpeting or upholstery from
other cleaning methods may cause excessive foam to
collect in the solution tank. If vacuum flooding occurs
foam and fluid will spill out onto the floor.
6. If flooding occurs turn off the pump switch.
7. Remove the vacuum hose from the machine.
8. Remove clear plastic lid.
9. Add DEFOAM to the tank according to bottle
instructions.
10. let vacuum run for 3-5 minutes to clear foam and dry
vacuum turbines.
11. Replace clear plastic lid.
12. Continue cleaning.
CAUTION!
If foam continues to cause
flooding, empty the solution tank and refill with fresh
fluid, adding CFR DEFOAM before restarting.
13. When finished cleaning, drive the Cascade to
the janitor’s closet or to where the waste
water can be dumped.
14. Follow instructions for routine daily maintenance.