CFR 10416A Instruction Manual Download Page 17

Ref #  Part # 

Description

01 

72505A  Handle, Cascade

02* 

X8261 

Screw, #6 x ? Phil Pan Black

03* 

72008A  Micro Switch

04* 

72382A  Bracket, Finger Swith

05* 

72398A  Handle, Finger Switch

06 

72510A  Handle Glide

07 

72056A  Screw, #8 x 5/8”, Self Tap

08* 

72566A  Motor Control, 125VDC

09 

70050B  Rocker, Switch, 15A, 2-Pole 

10 

72116A  Switch Cover, Blank

 

 

Replaced by 70050B for  

 

 

ozone models

11 

72387A  Screw, #8 x 5/8 Phil PH Black

Ref #  Part # 

Description

12* 

72579A  Knob, Speed Control

 

X8151C  Plug, 3/8” Hole, Plastic, Black

13 

72411A  Hour Meter, AC

 

71544A  Hour Meter, 230V

14 

7FC007  Circuit Breaker, 5A

 

7FC009  Circuit Breaker, 3A, 230V

 

7FC010  Circuit Breaker, 8A, 230V

 

7FC003  Circuit Breaker, 15A, 115V

15**  70895A  Rocket, Switch, 15A, 4 Pole
16 

PX112 

Pigtail, Black 12/3 SJT x 39”

17 

72570A  Screw, Long, Hex Head

18 

X8235 

Washer, ?” Flat USS Zinc

19 

72173A  Clip, Hand-Holding Spring

Ref #  Part # 

Description

20 

PD8 

  Strain Relief, ?” NPT

21 

72574A  Switch Panel, P-20

22 

X8282 

Bolt, ?-20 x 1” Hex SS

23 

X8008N  Nut, Lock, ?” Steel Conduit

24 

72434A  Jumper Tab #6

25 

72432A  Terminal Block, 7 Positions

26 

72361A  Panel, Motor Control

27 

X8256 

Nut, 8-32 Keps, Zinc

28 

72052A  Screw, #8 x 5/8, Phil Pan TS

29 

7BS002  Screw, 8-32 x ? Phil Pan

30 

71952A  Fiber Optic Cable --- OZ

* For self-propelled models only.
** Replace by 70050B in non SP model.

CFR CASCADE

17

Handle Assembly

Ref # 

Part # 

Description

01 

72438B 

Component Bracket

02* 

72566B 

Motor Control, 125VDC

 

72614A 

Motor Control, 230V ---SP

03** 

72052A 

Screw, #8 X 5/8 Phil Pan TS

 

 

 – Add 2 for 230V models

04***  71379A 

Relay, 25A, 120V

Ref # 

Part # 

Description

04 

71379B 

Relay, 230V -

 

 

 – Use 3 for 230V models

05 

72387A 

Screw, #8 x 5/8”, Black

06 

72434A 

Jumper, Tab #6

07 

72433A 

Terminal Block 3 Positions

09* 

72650A 

Fuse, 5A / 32V

Ref # 

Part # 

Description

09 

72649A 

Fuse, 3A / 32V --230V

10***  72430A 

Fuse Clip

11 

72388A 

Screw, #10 x 5/8 Phil Tap

* For self-propelled models only
** Use only three in non self-propelled models
*** Use only one in non self-propelled models

Component Panel Assembly 

Summary of Contents for 10416A

Page 1: ...machine IMPORTANT SAFETY INSTRUCTIONS This manual is to ensure that the CFR Cascade is operated correctly All operators must read understand and practice the following safety instructions Models 1041...

Page 2: ...and chemicals All operators of the equipment must watch the video and read the manual before using the equipment Please complete and return the enclosed warranty card Parts and Service The Cascade is...

Page 3: ...ide plates with the two holes in the bracket The side of the plate with the foam should be placed on the inside of the bracket 2 Secure the side plates to the tool head bracket using two black hex scr...

Page 4: ...ter only runs when the pump is on Trigger Activates solution dispensing WARNING Do not turn power off on the machine by disconnecting the cord The electronic drive control will sense a power failure a...

Page 5: ...sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces 7 Turn off all controls before unplugging 8 Do not unplug by pulling on cord To unplug grasp the plug not the c...

Page 6: ...length of the room overlap ping each pass by a minimum of 2 inches If you have an irregularly shaped room Establish a path down the length of the room at the longest point overlapping each pass by a...

Page 7: ...damage 4 Close the machine fastening the latches 5 Reconnect the vacuum hose and replace the clear tank lid The Cascade utilizes multiple filters in the recycling of cleaning solution It is imperative...

Page 8: ...hould never be higher than the inlet filter Doing so will activate the automatic vac uum shut off and the machine will not operate CAUTION Water temperature above 140 F 60 C will cause the tank to buc...

Page 9: ...e the trigger for 30 seconds Adjust p s i from 0 to 400 if necessary Note For P20 OZ models turn on vacuum pump and ozone switches on and let machine run for 15 minutes before use P20 The easy to use...

Page 10: ...um motor flooding and machine damage 5 When cleaning monitor foam in the solution tank Residue left in the carpeting or upholstery from other cleaning methods may cause excessive foam to collect in th...

Page 11: ...ll power is off 2 Empty the tank Remove the drain hose from the clamp on the rear of the machine Remove the plug and hold hose over the drain area until tank is empty 3 Remove clear plastic lid 4 Remo...

Page 12: ...ockage 6 Open and clean the in line strainer filter and replace Disconnect the in line strainer filter by using the quick disconnect coupler Remove any debris from the strainer Keep o ring and threads...

Page 13: ...a tighter seal 3 Wipe tool with damp cloth and store with head up to prevent clogging of nozzle OPTIONAL ACCESSORIES Wand and Tool Usage Attaching Wand Hand Tool The Cascade self contained cleaning sy...

Page 14: ...the surface being cleaned to produce maximum cleaning effectiveness and minimum dry times Upholstery 1 Place tool on surface to be cleaned 2 Move pull and push tool at a rate of about one foot per se...

Page 15: ...s lower check for air leaks in the tank cover gasket and drain hose 4 Check pump performance occasionally against built in pressure gauge Pump running pressure should be 380 400 p s i When pumping flu...

Page 16: ...aking fittings inline strainer Re prime pump Rebuild pump or pressure regulator if necessary Water dripping from bottom Check machine for excess foaming Add CFR Defoam to tool hose of machine exhaust...

Page 17: ...PD8 Strain Relief NPT 21 72574A Switch Panel P 20 22 X8282 Bolt 20 x 1 Hex SS 23 X8008N Nut Lock Steel Conduit 24 72434A Jumper Tab 6 25 72432A Terminal Block 7 Positions 26 72361A Panel Motor Control...

Page 18: ...lon 1 8 x 1 8 43 7AG002 Bushing 1 8 NPT 44 71492A Solenoid 1 8 Orifice 71545A Solenoid 1 8 Orifice 230V 45 7CX002 Nipple Hex MPT 46 7AR013 Nipple NPT x 3 L SS 47 PX6 Female Quick Disonnect 48 72539A B...

Page 19: ...sher 5 8 SAE Flat Zinc 33 7DT001 Bolt 5 16 18 x 5 8 Hex Tap 34 7CR004 Washer 5 16 USS Flat 35 72551A Caster 4 x 2 Wheel 36 72590A Screw 8 x 5 8 Oval Head 37 72568A Wand Holder 38 7AR013 Nipple NPT x 3...

Page 20: ...CFR CASCADE 20 Tank Assembly...

Page 21: ...15 70079C Hose Wire Reinforced 16 7DL008 Hose Clamp 17 71897A Gasket Filter Mount 18 72582A Decal Level Gauge 19 72588A Heat Shrink Tubing 20 SW139 Elbow 1 8 Street 21 7CX001 Nipple Hex 1 8 22 71576A...

Page 22: ...distributor or autho rized service repair center per the warranty flat rate schedule Service labor will be paid for two years on all warranted polyethylene housings aluminum frames and chassis and one...

Page 23: ...CFR CASCADE 23...

Page 24: ...Cascade SERIES P20 INSTRUCTION MANUAl 3101 Wichita Court n Fort Worth TX 76140 n 800 533 2557 n www cfrcorp com Models 10416A P20 SP 10419A P20 10425A P20 OZ SP 10426A P20 OZ 10427A P20 OZ SP 230V 104...