background image

CFR CASCADE

12

Tool Head

The P20 is designed to be tilted back 

for easy access to the tool head and 

underside of machine.  

Warning:

 Never tilt machine back 

when tank contains solution. 

1.  lower the tool head. 

2.  Disconnect the vacuum hose. 

3.  Disconnect and remove the tool head. 

A. Disconnect the solution hose. 

B. Remove the two quick release tool pins. 

C. Unscrew the two thumbscrews from each side of the 

    tool head and slide the tool head off. 

4.  Remove the spray bar and rinse. 

5.  Visually inspect quick disconnect spray tips 

for blockage. 

6.  Open and clean the in-line strainer filter and replace. 

• Disconnect the in-line strainer filter by using the 

  quick disconnect coupler.

• Remove any debris from the strainer. 

• Keep o-ring and threads of the plug lubricated. 

  CFR DEFOAM is a good lubricant or use a 

  non-petroleum based lubricant. This will ensure a 

  tighter seal.

7.  Remove any large debris from underneath the tool 

head. Rinse the vacuum chamber on the tool head. 

8.  Replace spray bar. 

9.  Connect the tool head. 

• Connect the solution hose. 

• Replace the two quick release tool pins. 

• Replace the two thumbscrews from each side of 

  the tool head. 

10. Connect the vacuum hose. 

11. Raise the tool head for storage. 

B

C

4

6

A

Spray tips

Spray bar

In-line strainer

Vacuum chamber

Summary of Contents for 10416A

Page 1: ...machine IMPORTANT SAFETY INSTRUCTIONS This manual is to ensure that the CFR Cascade is operated correctly All operators must read understand and practice the following safety instructions Models 1041...

Page 2: ...and chemicals All operators of the equipment must watch the video and read the manual before using the equipment Please complete and return the enclosed warranty card Parts and Service The Cascade is...

Page 3: ...ide plates with the two holes in the bracket The side of the plate with the foam should be placed on the inside of the bracket 2 Secure the side plates to the tool head bracket using two black hex scr...

Page 4: ...ter only runs when the pump is on Trigger Activates solution dispensing WARNING Do not turn power off on the machine by disconnecting the cord The electronic drive control will sense a power failure a...

Page 5: ...sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces 7 Turn off all controls before unplugging 8 Do not unplug by pulling on cord To unplug grasp the plug not the c...

Page 6: ...length of the room overlap ping each pass by a minimum of 2 inches If you have an irregularly shaped room Establish a path down the length of the room at the longest point overlapping each pass by a...

Page 7: ...damage 4 Close the machine fastening the latches 5 Reconnect the vacuum hose and replace the clear tank lid The Cascade utilizes multiple filters in the recycling of cleaning solution It is imperative...

Page 8: ...hould never be higher than the inlet filter Doing so will activate the automatic vac uum shut off and the machine will not operate CAUTION Water temperature above 140 F 60 C will cause the tank to buc...

Page 9: ...e the trigger for 30 seconds Adjust p s i from 0 to 400 if necessary Note For P20 OZ models turn on vacuum pump and ozone switches on and let machine run for 15 minutes before use P20 The easy to use...

Page 10: ...um motor flooding and machine damage 5 When cleaning monitor foam in the solution tank Residue left in the carpeting or upholstery from other cleaning methods may cause excessive foam to collect in th...

Page 11: ...ll power is off 2 Empty the tank Remove the drain hose from the clamp on the rear of the machine Remove the plug and hold hose over the drain area until tank is empty 3 Remove clear plastic lid 4 Remo...

Page 12: ...ockage 6 Open and clean the in line strainer filter and replace Disconnect the in line strainer filter by using the quick disconnect coupler Remove any debris from the strainer Keep o ring and threads...

Page 13: ...a tighter seal 3 Wipe tool with damp cloth and store with head up to prevent clogging of nozzle OPTIONAL ACCESSORIES Wand and Tool Usage Attaching Wand Hand Tool The Cascade self contained cleaning sy...

Page 14: ...the surface being cleaned to produce maximum cleaning effectiveness and minimum dry times Upholstery 1 Place tool on surface to be cleaned 2 Move pull and push tool at a rate of about one foot per se...

Page 15: ...s lower check for air leaks in the tank cover gasket and drain hose 4 Check pump performance occasionally against built in pressure gauge Pump running pressure should be 380 400 p s i When pumping flu...

Page 16: ...aking fittings inline strainer Re prime pump Rebuild pump or pressure regulator if necessary Water dripping from bottom Check machine for excess foaming Add CFR Defoam to tool hose of machine exhaust...

Page 17: ...PD8 Strain Relief NPT 21 72574A Switch Panel P 20 22 X8282 Bolt 20 x 1 Hex SS 23 X8008N Nut Lock Steel Conduit 24 72434A Jumper Tab 6 25 72432A Terminal Block 7 Positions 26 72361A Panel Motor Control...

Page 18: ...lon 1 8 x 1 8 43 7AG002 Bushing 1 8 NPT 44 71492A Solenoid 1 8 Orifice 71545A Solenoid 1 8 Orifice 230V 45 7CX002 Nipple Hex MPT 46 7AR013 Nipple NPT x 3 L SS 47 PX6 Female Quick Disonnect 48 72539A B...

Page 19: ...sher 5 8 SAE Flat Zinc 33 7DT001 Bolt 5 16 18 x 5 8 Hex Tap 34 7CR004 Washer 5 16 USS Flat 35 72551A Caster 4 x 2 Wheel 36 72590A Screw 8 x 5 8 Oval Head 37 72568A Wand Holder 38 7AR013 Nipple NPT x 3...

Page 20: ...CFR CASCADE 20 Tank Assembly...

Page 21: ...15 70079C Hose Wire Reinforced 16 7DL008 Hose Clamp 17 71897A Gasket Filter Mount 18 72582A Decal Level Gauge 19 72588A Heat Shrink Tubing 20 SW139 Elbow 1 8 Street 21 7CX001 Nipple Hex 1 8 22 71576A...

Page 22: ...distributor or autho rized service repair center per the warranty flat rate schedule Service labor will be paid for two years on all warranted polyethylene housings aluminum frames and chassis and one...

Page 23: ...CFR CASCADE 23...

Page 24: ...Cascade SERIES P20 INSTRUCTION MANUAl 3101 Wichita Court n Fort Worth TX 76140 n 800 533 2557 n www cfrcorp com Models 10416A P20 SP 10419A P20 10425A P20 OZ SP 10426A P20 OZ 10427A P20 OZ SP 230V 104...

Reviews: