Never expose eyes or skin to UVC light from any source. Looking directly at the UVC

light may cause permanent eye damage or blindness. Never operate the CX-Aire Air Purifying System
out of the plenum. Avoid touching the glass portion of the lamp with your hands.

WARNING

CX-AIRE IN-DUCT AIR PURIFIER

MODEL:  CX-Aire

The delivery set includes: 

Ballast assembly and power cord

Mounting base

UVC germicidal lamp

UVC light shield

Sheet metal mounting screws (6)

Mounting template 

Ductboard adapter plate

This product is not sold as a medical device and is not for the purpose of

diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention
of any disease or condition.

Note: 

For applications with multiple systems, one unit per system is recommended. 

For larger applications, multiple units are recommended. 

BEFORE INSTALLATION

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING

WITH THE INSTALLATION.

Disconnect and lock out power supply before performing any installation work.

Working on or near energized equipment could result in death or serious injury.

This device MUST be installed by a qualified agency in accordance with the manufacturer's installation
instructions. The definition of a qualified agency is any individual, firm, corporation or company that
either in person or through a representative is engaged in, and is responsible for, the installation and
operation of HVAC appliances, who is experienced in such work, familiar with all the precautions
required, and has complied with all the requirements of the authority having jurisdiction.

SIZING & SELECTING UNITS

SQUARE

FOOTAGE

CX-AIRE

(for ducts at least 16” wide)

VOLTS / HZ

WATTS

AMPS

Up to 2000

1

120 / 60

30

.5

4000

2

120 / 60

30

.5

NOTICE

WARNING

NOTICE

Summary of Contents for CX-AIRE

Page 1: ...Installation Maintenance CX AIRE IN DUCT AIR PURIFIER READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...ercury After opening the carton unpack and inspect the unit and lamp for damage Do not install this unit if any damage is noticeable If lamp is damaged cracked or broken do not touch lamp or other con...

Page 3: ...ended For larger applications multiple units are recommended BEFORE INSTALLATION READTHESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION Disconnect and lock out power s...

Page 4: ...as possible to the AC coil Figure 1 E Mount the UV lamp unit not less than 181 ft in the line of sight to any openings in the air duct and not less than 44 ft in the line of sight to any non metallic...

Page 5: ...STALLATION STEP 2 MOUNTING TEMPLATE OR DUCTBOARD ADAPTER PLATE A or B NOTE If installing on sheet metal air duct follow step A using the the supplied mounting template If mounting onto a fiberglass du...

Page 6: ...ure 4 a Mount the supplied metal mounting plate onto the duct with duct tape in either a vertical or horizontal position Figure 5 b Bend tabs outward Figure 6 c Using a knife or blade cut out a rectan...

Page 7: ...at the UVC light may cause permanent eye damage or blindness Never operate the CX Aire Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands WARNING INST...

Page 8: ...on a suitable location the mounting screw head cannot be in the shaded area of template Figure 14 B Press shield onto duct wall Then secure with 2 sheet metal mounting screws Figure 15 STEP 4 MOUNTIN...

Page 9: ...ided Plug the power supply cord into a standard 120VAC electric outlet Check lamp operation by looking through the viewport hole NOTE The viewport hole is made of glass and will not allow any UVC rays...

Page 10: ...up rotate ballast slightly clockwise or counterclockwise 5 If lamp does not light up after rotating ballast replace lamp 6 If unit still does not light up after replacing lamp replace unit RECOMMENDE...

Page 11: ...el and apply to the side of ballast assembly NOTE If blue light leaks through any portion of plenum and or around mounting plate unplug power supply cord immediately and seal affected areas and or rot...

Page 12: ...ives electrical controls and other components manufactured for Vendor by others are not covered by these warranty provisions All warranty claims must be processed through point of purchase All warrant...

Reviews: