background image

5

Optional UVC light shield mounting:
Head of mounting screw
cannot be located in shaded area.

Drill mounting holes
using 1/8” drill bit 
(4 holes)

Drill viewport hole
using 1/4” to 1/2” drill bit

Center of
mounting base

Drill 1-1/2” diameter

Mounting template 

    
Mount unit either
horizontal or vertical

Duct

Figure 2

Figure 3

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC

light may cause permanent eye damage or blindness. Never operate the CX-Aire Air Purifying System
out of the plenum. Avoid touching the glass portion of the lamp with your hands.

WARNING

INSTALLATION

STEP 2. MOUNTING TEMPLATE OR DUCTBOARD ADAPTER PLATE (A or B)

NOTE:

If installing on sheet metal air duct, follow step A using the the supplied mounting template.

If mounting onto a fiberglass ductboard, follow step B (page 6) using the ductboard adapter plate.

Investigate and determine the location of the AC coil prior to drilling holes in duct

for mounting unit.

A.  Pre-drilling with mounting template 

a.

Apply supplied mounting template to air duct in either a vertical or horizontal position
(Figure 2). 

b. 

Drill 1⁄ 8" diameter mounting holes at positions indicated on template (Figure 3).

c. 

Cut out the large opening (1-1⁄ 2" hole) on the template (Figure 3). 

d. 

Using a 1⁄ 4" to 1⁄ 2" drill bit, drill a viewport hole as indicated on the template (Figure 3). 

NOTE:  

DO NOT remove template from duct.

CAUTION

Summary of Contents for CX-AIRE

Page 1: ...Installation Maintenance CX AIRE IN DUCT AIR PURIFIER READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...ercury After opening the carton unpack and inspect the unit and lamp for damage Do not install this unit if any damage is noticeable If lamp is damaged cracked or broken do not touch lamp or other con...

Page 3: ...ended For larger applications multiple units are recommended BEFORE INSTALLATION READTHESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION Disconnect and lock out power s...

Page 4: ...as possible to the AC coil Figure 1 E Mount the UV lamp unit not less than 181 ft in the line of sight to any openings in the air duct and not less than 44 ft in the line of sight to any non metallic...

Page 5: ...STALLATION STEP 2 MOUNTING TEMPLATE OR DUCTBOARD ADAPTER PLATE A or B NOTE If installing on sheet metal air duct follow step A using the the supplied mounting template If mounting onto a fiberglass du...

Page 6: ...ure 4 a Mount the supplied metal mounting plate onto the duct with duct tape in either a vertical or horizontal position Figure 5 b Bend tabs outward Figure 6 c Using a knife or blade cut out a rectan...

Page 7: ...at the UVC light may cause permanent eye damage or blindness Never operate the CX Aire Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands WARNING INST...

Page 8: ...on a suitable location the mounting screw head cannot be in the shaded area of template Figure 14 B Press shield onto duct wall Then secure with 2 sheet metal mounting screws Figure 15 STEP 4 MOUNTIN...

Page 9: ...ided Plug the power supply cord into a standard 120VAC electric outlet Check lamp operation by looking through the viewport hole NOTE The viewport hole is made of glass and will not allow any UVC rays...

Page 10: ...up rotate ballast slightly clockwise or counterclockwise 5 If lamp does not light up after rotating ballast replace lamp 6 If unit still does not light up after replacing lamp replace unit RECOMMENDE...

Page 11: ...el and apply to the side of ballast assembly NOTE If blue light leaks through any portion of plenum and or around mounting plate unplug power supply cord immediately and seal affected areas and or rot...

Page 12: ...ives electrical controls and other components manufactured for Vendor by others are not covered by these warranty provisions All warranty claims must be processed through point of purchase All warrant...

Reviews: