OMT WG Adaptor Installation
This procedure is applicable for all remote mount configurations that involve
an OMT.
1 For 6Ghz (UDR70):
i Mount the O-Ring supplied with the OMT kit.
ii Mount OMT Adaptor #1 on the OMT, and tighten using four M4 screws
and washers (supplied with the OMT adaptor kit).
iii Mount OMT Adaptor #2 on OMT Adaptor #1, and tighten using four M4
screws and washers (supplied with the OMT adaptor kit).
iv Mount the flexible waveguide as usual.
2 For 7-11 GHz (UBR84 and UBR100):
i Mount the O-Ring supplied with the OMT kit.
ii Mount the OMT adaptor, with its installed sealing gasket, on the OMT,
and tighten using the four M4 screws and washers supplied with the
OMT Adaptor kit.
iii Mount the flexible waveguide without its gasket (only for the OMT
side).