Procedure
1 Fit the interface plate to the hub mounting ring using six of the c'sk screws
that are supplied.
i Make sure that the interface plate has been properly located before
tightening to a torque of 10Nm±5%. Refer to Step 6 for polarization
settings.
ii Make sure that the timing pin is located in the timing recess in the
interface plate.
2 Remove the protective tape.
3 Assemble the small o-ring to feed.
4 Smear a small amount of silicon grease onto the O-Ring (two and three feet
ONLY).