FibeAir® RFU-C
Installation Guide
Ceragon Proprietary and Confidential
Page 17 of 93
5.
Cable Installation and Grounding
List of Items
Item Description
Quantity Remarks
1
IF RG-8 GRD KIT
1
Procedure
1 On the front side of each RFU-C unit, loosen the nut, plain washer, and
serrated washer.
2 Place the cable lug (supplied with the RFU-C grounding kit) on the screw.
3 Secure the cable lug.
RFU-C Grounding Cable
The unit’s earthing screw terminal shall be permanently connected to
protective earth in a building installation in accordance with applicable
national code and regulations by a service person.
A 2-Pole circuit breaker, a branch circuit protector, suitably certified in
accordance with applicable national code and regulations, rated maximum
20A, shall be installed for full power disconnection in a building
installation.
Any outdoor antenna cable shield shall be permanently connected to
protective earth in a building installation.