background image

- 15 -

SDOPD

OPTIONS AND FEATURES

19. Learn Button

The Learn button (Fig 11) is located on the rear cover of the AGDO and serves to initiate the functions as

described in the following table;

Function

Action

Reference

Learn Hand Transmitter Codes

Momentary press

Sec.15

Delete Hand Transmitter Codes

Press and hold while powering-up

Sec.15

Entering SOF Adjustment Mode

Press and hold for 2 sec.

Sec.14

20. LED Indicator

The LED Indicator (Fig 11) is located on the rear cover of the AGDO and serves to provide visual

indication of functionality sequences as described in the following table;

Display

Indicator

Glow Solid

Reached door closed position

Slow Flash

Reached door open position

Medium Flash

Learning or deleting Hand Transmitter codes

Quick Flash

Force adjust mode activated

None

AGDO is traveling between open and closed positions

21. Output Terminals

4 Output Terminals (Fig.11) are provided within the back cover of the AGDO to support the connection

of the following accessories;

a. Genuine 2 wire Safety Beams (Fig 12A)

b. 24VDC universal receiver (Fig 12B)

c. Normally open momentary contact Wall Switch (Fig 12)

Fig 12A

Fig 12B

Fig 12C

22. Run Button

The Run button (Fig.11) is located on the rear cover of the AGDO and serves to initiate the following

functions;

Function

Action

Activate AGDO

Momentary press

Safety Beam override

Press and hold until garage door is fully closed

23. Safety Beams

Genuine 2 wire Safety Beams may be connected to the AGDO.

The installation of Safety Beams greatly enhances safety by constantly monitoring for persons or objects

that might pass within the path of the moving garage door. The AGDO will commence to safety reverse if

the Safety Beams become momentarily or permanently interrupted while the garage door is closing.

Summary of Contents for SDO-10

Page 1: ...1 IMPORTANT SAFETY RECOMMENDATIONS 802 011 01 D...

Page 2: ...2 SDOPD...

Page 3: ...ower Head to Ceiling 9 Attaching Towing Arms 9 Adjusting Disengage Cord 10 Connecting to Power Supply 10 Settings and Adjustments 11 Disengaging from Garage Door 11 Engaging to Garage Door 11 Travel A...

Page 4: ...llation of the AGDO 6 The counter balance springs on sectional type garage doors must be lubricated annually between each of the coils with heavy automotive bearing grease Failure to adequately lubric...

Page 5: ...ving out of its view 25 Adjustments to the Safety Obstruction Force settings must only be carried out by a technically qualified person Attempting to adjust the settings without suitable technical qua...

Page 6: ...sembling Drive Pole and Power Head Refer to Figs 1A C in order to identify Garage Door type and length of rail required On a clean smooth surface unpack the Power Head Drive Pole Carriage and Terminal...

Page 7: ...ensuring that the teeth of the Chain Sprocket engage into the links of the Drive Chain Fig 4 Extend the remainder of the Drive Chain back to the Bullet Fig 4 Fig 4A Fig 4B Fig 4C Turn the Lock Nut all...

Page 8: ...l member of the garage door Mark the location of at least 2 screw holes as far apart from each other as possible Drill the 2 screw holes with appropriate drill and securely mount the Towing Bracket to...

Page 9: ...the floor along both planes For Sectional and Track Type Tilt Doors only For Jamb Type Tilt Door refer Fig 1B Important Notes a With the garage door in the fully open position the underside of the Dri...

Page 10: ...o that the end hangs approximately 1800mm above the garage floor Fig 9 Fig 9 10 Connecting to Power Supply Connect the AGDO to a properly earthed power supply using the Power Cord provided Important N...

Page 11: ...ustment Close Direction Garage Door Travel Adjustment Locate the 2 Door Travel Adjusting Screws DTAS found on the underside of the Power Head Fig 10 Increase Travel turn the DTAS marked with the Red a...

Page 12: ...pen As the garage door is opening slowly turn the Open Force green adjustment pin Fig 11 in an anti clockwise direction until the garage door stops Now turn the same pin clockwise 5 degrees Safety Obs...

Page 13: ...bottom of the garage door is resting lightly on the floor of the garage refer Sec 13 for door travel adjustment instructions 15 Hand Transmitters Code Learning The AGDO can store up to 14 individual...

Page 14: ...3 Dip No 4 15 off off 30 on off 45 off on 60 on on 17 Courtesy Lamp The in built Courtesy Lamp will illuminate each time the AGDO is activated and then switch off automatically 3 min after receiving...

Page 15: ...None AGDO is traveling between open and closed positions 21 Output Terminals 4 Output Terminals Fig 11 are provided within the back cover of the AGDO to support the connection of the following access...

Page 16: ...e is glowing red Adjust the Emitter Safety Beam module by turning the mounting bracket so that it is aimed directly at the lens of the Receiver Safety Beam module An indicator lamp located along the t...

Page 17: ...rage The Wireless Wall Switch may be learned into the AGDO as per the procedure outlined in Sec 15 Hand Transmitter Code Learning The switch can be permanently screwed to the wall through the mounting...

Page 18: ...Stop Check function of AGDO by operating from Run button 15 23 AGDO will not function from Check function of AGDO by learning in a substitute Hand Transmitter 13 16 Hand Transmitter Re learn Hand Tran...

Page 19: ...19 SDOPD NOTES...

Reviews: