Series VC-50 / SVC-50 / MVC-50 / LVC-50
49-MCVC50EN03
10
USER´S MANUAL
9. INTERFACE RS-232
These indicators can include an optional RS-232 interface.
Specifications:
•
RS-232 interface for weighing data
•
ASCII
code
•
8 data bits
•
Non-parity
Connector: 9 pin SUB-D type
•
Pin
2:
Tx
•
Pin 3:
Rx (not used)
•
Pin
5:
GND
Data format differs in normal weighing mode, item counting mode and memory total retrieval. Examples:
Normal output
When items are counted, the unit weight and count will be printed.
When the total weight stored in the accumulative memory is retrieved, the outgoing format is:
GS 12.340kg
GW for gross weight, NT for net weight and unit of weight
No. 1
This number increases each time a new value is stored in the memory.
Total 12.340kg
Total value stored in the memory
<lf>
Includes two line-feed characters
<lf>
***************
Line of stars is shown
<lf>
Includes line-feed character
TOTAL
No. 5
Weight 21.455kg
.
***************
GS 12,.40kg
GW for gross weight, NT for net weight and unit of weight
U.W. 123.4g/pcs
The mean weight per item, calculated by the scales
PCS 100pcs
Total number of items counted
<lf>
Includes two line-feed characters
<lf>