Series VC-50 / SVC-50 / MVC-50 / LVC-50
49-MCVC50EN03
6
USER´S MANUAL
6.5.2. Setting the limits
Press
and the display will show “F0 H-L”. Press
to enter, use
to select “SET HI” or “SET LO”,
press
to enter. Use
or
to move the active digit and
to change the value. Use
to delete the
value. After entering the value, press
to save and
to exit.
6.5.3. Setting the alarm
Press
to enter set-up mode, press
until the display shows “F4 OFF”, press
to enter and
until
the display shows “BEEP”. Then press
to enter and
to select BP 2 (weight check mode 2), BP3
(weight check mode 3), BP1(no sound), press
to save changes and
to exit.
NOTE:
The weight must be greater than 20 scale divisions for the weight control function to operate.
To deactivate the weight control function, set both limits to zero by pressing
when the current values are
shown. Then press
to save the zero values.
6.6. ACCUMULATED
TOTAL
The scales can be set to manual accumulation by pressing
. Refer to the CONFIGURATION section for
further details on selecting this method using "F5 PRT”. The accumulation function is only available when the
scales are in weighing mode. It is deactivated in item counting mode.
The weight that appears on the display will be saved in the memory if
is pressed when the weight is
stable.
The display will show “ACC 1” and the total saved in the memory will be displayed for two seconds before
returning to normal mode. If the optional RS-232 interface is installed, the weight will be sent to a printer or
PC (this type of machine does not have a print function).
Remove the weight so that the scales return to zero and put another weight on the platform. Press
and
the display will show “ACC 2” followed by the new total.
Continue until all the weights have been added.
In order to view the totals in the memory, go to the CONFIGURATION section and use the function “F1
TOL”.
6.7. WEIGHING SCALES FOR ANIMALS
The VC-50 / SVC-50 / MVC-50 / LVC-50 models can also be used as weighing scales for animals if the
external resolution is below 1/3000. To set the scales up in this mode, refer to the Technical Configuration for
VC-50 / SVC-50 / MVC-50 / LVC-50.
Place the animal on the platform. After a few seconds, if the data reading falls within the upper and lower
limits that have been set, a beep will sound to indicate that the data reading is being recorded. After the
animal has been taken off the scales, the data reading display will return to zero and the VC-50 / SVC-50 /
MVC-50 / LVC-50 will automatically perform the accumulation operation. If the mini-printer is connected, the
VC-50 / SVC-50 / MVC-50 / LVC-50 will print automatically.
To delete the accumulative memory, press
when the scales are at ZERO.
This function is only available in the animal weighing mode.