www.cellarcool.com | Page 21
CM2500
www.whisperkool.com | Page 21
Mini Ceiling Mount
Condensation Drain Line
DRAIN LINE
The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location. It
is important that the drain line tube is properly connected.
Failure to use the condensation drain line tube will void the warranty on the unit.
Drain Line
The Mini Ceiling Mount evaporator unit features a drain line pump system that removes excessive condensate build
up in the drain pan. During operation, the drain pan collects water that drips from the coil. The drain line pump
system will prevent overflow and leaking by allowing for discharge of the additional condensate.
Connecting the Drain Line
Route the drain line to an appropriate discharge location and connect the opposite end to
the tubing that was routed out with the line set using the provided barbed coupler side of the
condensate pump. Do not route the drain line more than 15 vertical ft.
To prevent mold from growing, allow the
drain line to hang above the water line.
WRONG: Drain line is under water.
Proper Discharge
Location