Ceiec Electric PMC-630 E User Manual Download Page 75

 

 

75   

Ceiec Electric Technology 

168 

Ib 14

th

 Harmonic 

x10000 

169 

Ic 14

th

 Harmonic 

x10000 

170 

Ia 15

th

 Harmonic 

x10000 

171 

Ib 15

th

 Harmonic 

x10000 

172 

Ic 15

th

 Harmonic 

x10000 

173 

Ia 16

th

 Harmonic 

x10000 

174 

Ib 16

th

 Harmonic 

x10000 

175 

Ic 16

th

 Harmonic 

x10000 

176 

Ia 17

th

 Harmonic 

x10000 

177 

Ib 17

th

 Harmonic 

x10000 

178 

Ic 17

th

 Harmonic 

x10000 

179 

Ia 18

th

 Harmonic 

x10000 

180 

Ib 18

th

 Harmonic 

x10000 

181 

Ic 18

th

 Harmonic 

x10000 

182 

Ia 19

th

 Harmonic 

x10000 

183 

Ib 19

th

 Harmonic 

x10000 

184 

Ic 19

th

 Harmonic 

x10000 

185 

Ia 20

th

 Harmonic 

x10000 

186 

Ib 20

th

 Harmonic 

x10000 

187 

Ic 20

th

 Harmonic 

x10000 

188 

Ia 21

st

 Harmonic 

x10000 

189 

Ib 21

st

 Harmonic 

x10000 

190 

Ic 21

st

 Harmonic 

x10000 

191 

Ia 22

nd

 Harmonic 

x10000 

192 

Ib 22

nd

 Harmonic 

x10000 

193 

Ic 22

nd

 Harmonic 

x10000 

194 

Ia 23

rd

 Harmonic 

x10000 

195 

Ib 23

rd

 Harmonic 

x10000 

196 

Ic 23

rd

 Harmonic 

x10000 

197 

Ia 24

th

 Harmonic 

x10000 

198 

Ib 24

th

 Harmonic 

x10000 

199 

Ic 24

th

 Harmonic 

x10000 

200 

Ia 25

th

 Harmonic 

x10000 

201 

Ib 25

th

 Harmonic 

x10000 

202 

Ic 25

th

 Harmonic 

x10000 

203 

Va Demand 

x100, V 

204 

Vb Demand 

x100, V 

205 

Vc Demand 

x100, V 

206 

VLN avg. Demand 

x100, V 

207 

Vab Demand 

x100, V 

208 

Vbc Demand 

x100, V 

209 

Vca Demand 

x100, V 

210 

VLL avg. Demand 

x100, V 

211 

Ia Demand 

x1000, A 

212 

Ib Demand 

x1000, A 

213 

Ic Demand 

x1000, A 

214 

I avg. Demand 

x1000, A 

215 

I4 Demand 

x1000, A 

216 

kWa Demand 

217 

kWb Demand 

218 

kWc Demand 

219 

∑kW Demand 

220 

kvara Demand 

var 

221 

kvarb Demand 

var 

222 

kvarc Demand 

var 

223 

∑kvar Demand 

var 

224 

kVAa Demand 

VA 

225 

kVAb Demand 

VA 

226 

kVAc Demand 

VA 

227 

∑kVA Demand 

VA 

228 

P.F.a Demand 

x1000 

229 

P.F.b Demand 

x1000 

230 

P.F.c Demand 

x1000 

231 

∑P.F. Demand 

x1000 

232 

Freq. Demand 

x100, Hz 

233 

U Unbalance Demand 

x1000 

234 

I Unbalance Demand 

x1000 

235 

Va THD Demand 

x10000 

236 

Vb THD Demand 

x10000 

237 

Vc THD Demand 

x10000 

238 

Ia THD Demand 

x10000 

239 

Ib THD Demand 

x10000 

240 

Ic THD Demand 

x10000 

241 

Va max 

per Demand Period 

x100, V 

242 

Vb max 

per Demand Period 

x100, V 

243 

Vc max 

per Demand Period 

x100, V 

244 

VLN avg. max 

Per Demand Period 

x100, V 

245 

Vab max 

per Demand Period 

x100, V 

246 

Vbc max 

x100, V 

247 

Vca max 

x100, V 

Summary of Contents for PMC-630 E

Page 1: ...PMC 630 E Advanced Multifunction Ethernet Meter User Manual Version V1 0A 07 03 2013 Ceiec Electric Technology...

Page 2: ...the right to make changes without notice Please consult CET or your local representative for latest product specifications Standards Compliance DANGER This symbol indicates the presence of danger tha...

Page 3: ...n During normal operation of the meter hazardous voltages are present on its terminal strips and throughout the connected potential transformers PT and current transformers CT PT and CT secondary circ...

Page 4: ...es not accept liability for any damage caused by meter malfunctions CET accepts no responsibility for the suitability of the meter to the application for which it was purchased Failure to install set...

Page 5: ...3 wire Open Delta with 2PTs and 3CTs 17 2 4 7 3 phase 3 wire Open Delta with 2PTs and 2CTs 17 2 5 Communications Wiring 18 2 5 1 RS485 Port 18 2 5 2 Ethernet Port 10 100BaseT 18 2 6 Digital Input Wiri...

Page 6: ...r 46 5 1 1 Basic Measurements 46 5 1 2 Energy Measurements 48 5 1 3 Pulse Counter 49 5 1 4 Harmonic Measurements 49 5 1 5 Present Demand 51 5 1 6 Max Min Value per Demand Period 52 5 1 7 Peak Demand L...

Page 7: ...Log Data Structure 71 5 11 5 Waveform Recorder Setup Data Structure 71 5 11 6 SOE Log Data Structure 72 Revision History 72 Appendix A Data Recorder Parameter 73 Appendix B Event Classification 78 Ap...

Page 8: ...int status changes and RO operations in 1ms resolution With the standard RS485 port and 10 100BaseT Ethernet port supporting Modbus RTU and Modbus TCP protocols the PMC 630E becomes a vital component...

Page 9: ...rmat from 128x5 64x10 32x20 to 16x40 with up to 5 pre fault cycles Support FIFO recording mode Data Recorder Log 16 Data Recorder Logs of 16 parameters each for real time measurements harmonics interv...

Page 10: ...rom 1200 to 38400bps Modbus RTU protocol System Integration Supported by our PecStar iEMS iEEM and iPQMS Easy integration into other Automation or SCADA systems via Modbus RTU and Modbus TCP protocols...

Page 11: ...Technology 1 4 Getting more information Additional information is available from CET via the following sources Visit www ceiec electric com Contact your local representative Contact CET directly via e...

Page 12: ...nt personnel that have the appropriate training and experience with high voltage and current devices The meter must be installed in accordance with all local and national electrical codes During the o...

Page 13: ...dry environment with no dust and kept away from heat radiation and electrical noise sources Installation steps Remove the mounting slide bars from the meter Fit the meter through a 92mmx92mm cutout a...

Page 14: ...s and 3CTs 3 phase 3 wire Open Delta Direct Connection 3 phase 3 wire Open Delta with 3PTs and 3CTs 3 phase 3 wire Open Delta with 3PTs and 2CTs 2 4 1 3 phase 4 wire Wye Direct Connection Please consu...

Page 15: ...al to the meter s voltage input specification Set the Wiring Mode to Wye Figure 2 5 4 Wire Wye 3PTs 3CTs 2 4 3 3 phase 3 wire Grounded Wye Direct Connection Please consult the serial number label to e...

Page 16: ...equal to the meter s voltage input specification Set the Wiring Mode to Wye Figure 2 7 3 Wire Grounded Wye 3PTs 3CTs 2 4 5 3 phase 3 wire Open Delta Direct Connection Please consult the serial number...

Page 17: ...r equal to the meter s voltage input specification Set the Wiring Mode to Delta Figure 2 9 3 Wire Delta 2PTs 3CTs 2 4 7 3 phase 3 wire Open Delta with 2PTs and 2CTs Please consult the serial number la...

Page 18: ...port a RS232 RS485 or USB RS485 converter with optically isolated outputs and surge protection should be used The following figure illustrates the RS485 communications connections on the PMC 630E Figu...

Page 19: ...ons 2 8 Power supply Wiring For AC supply connect the live wire to the L terminal and the neutral wire to the N terminal For DC supply connect the positive wire to the L terminal and the negative wire...

Page 20: ...The front panel provides two display modes Data Display and Setup Configuration There are four buttons on the front panel V I Power Harmonics and Energy Use these buttons to view metering data and co...

Page 21: ...gle Current Phase Angle Demand etc B Displays the indicators for DI status and RO status C Displays Measurement Units Loading Factor and PF Quadrant indicator D Displays Measurement values E Displays...

Page 22: ...C Units for Voltage Current Harmonics Distortion and Frequency Units for Real Reactive and Apparent Power Loading Inductive Load Capacitive Load COM 1 Port Status COM 2 Port Status Alarm Symbol PF Qu...

Page 23: ...Display Area Symbol Description a kW kvar kVA Phase A Phase B Phase C Demand Maximum This Month Last Month b Peak Demand Value c Peak Demand Timestamp Date Portion YYYY MM DD d Peak Demand Timestamp T...

Page 24: ...Month YYYY MM DD HH MM SS Display 18 Ib Peak Demand of Last Month YYYY MM DD HH MM SS Display 19 Ic Peak Demand of Last Month YYYY MM DD HH MM SS Power Display 1 1 kWa kWb kWc kW Display 2 1 kvara kva...

Page 25: ...play 66 Va 31 st Harmonic Vb 31 st Harmonic Vc 31 st Harmonic VLN avg 31 st Harmonic Display 67 Ia 31 st Harmonic Ib 31 st Harmonic Ic 31 st Harmonic I avg 31 st Harmonic Energy Display 1 kWh Import D...

Page 26: ...r goes back to the last value in the selection list V I Once a parameter is selected for modification pressing this button moves the cursor to the left by one position if the parameter being changed i...

Page 27: ...27 Ceiec Electric Technology 3 2 2 Setup Menu Figure 3 5 Setup Menu...

Page 28: ...000 1 CT CT Ratio 1 CT Ratio 1 to 30 000 1A 1 to 6 000 5A 1 I4 I4 Ratio I4 Ratio 1 to 10 000 1 PF SET P F Convention 2 P F Convention IEC IEEE IEEE IEC KVA SET kVA Calculation 3 kVA Calculation Metho...

Page 29: ...xample Subnet Mask is 255 255 255 0 Subnet Mask high order is 255 255 255 255 SML Subnet Mask Subnet Mask low order For example Subnet Mask is 255 255 255 0 Subnet Mask low order is 255 0 255 0 GWH Ga...

Page 30: ...MAL CLR SET Clear Logs YES NO NO CLR ENGY Clear Energy Clear kWh kvarh and kVAh YES NO NO CLR MXMN Clear Max Min Clear Max Min Logs of This Month YES NO NO CLR PDMD Clear Demand Clear Peak Demands of...

Page 31: ...r 5A configuration PT Ratio CT Ratio must be less than 1 000 000 For 1A configuration PT Ratio x CT Ratio must be less than 5 000 000 2 P F Convention IEEE is the same as IEEE but with the opposite si...

Page 32: ...n X100 U U 2 K 1 K k Current K th Harmonic Distortion X100 I I 2 K 1 K k 5 The Backlight Time out can be set from 0 to 60 minutes If the value is 0 the backlight is always on 6 The IP Port No for the...

Page 33: ...tandard with three Form A Electromechanical Digital Outputs Digital Outputs are normally used for setpoint alarming load control or remote control applications Digital Outputs on the PMC 630E can be u...

Page 34: ...tage and Current phase angles 4 2 2 Phase Angle Phase analysis is used to identify the angle relationship between the three phase voltages and currents For Wye connected systems the per phase differen...

Page 35: ...nd P F b Demand Vb Demand kWb Demand P F c Demand Vc Demand kWc Demand P F Demand VLN average Demand kW Demand FREQ Demand Vab Demand kvara Demand Voltage Unbalance Demand Vbc Demand kvarb Demand Curr...

Page 36: ...t Active Limit Specify the value that the setpoint parameter must exceed for Over Setpoint or go below for Under Setpoint for the setpoint to become active 3 Setpoint Inactive Limit Specify the value...

Page 37: ...I2 11 DI3 12 DI4 13 DI5 14 DI6 15 Reserved 16 kW Demand kW 17 kvar Demand kvar 18 P F Demand x1000 19 V THD x100 20 V TOHD x100 21 V TEHD x100 22 I THD x100 23 I TOHD x100 24 I TEHD x100 25 Voltage Un...

Page 38: ...Peak Demand of Last Month kvar Peak Demand of This Month kvar Peak Demand of Last Month kVA Peak Demand of This Month kVA Peak Demand of Last Month Ia Peak Demand of This Month Ia Peak Demand of Last...

Page 39: ...Vc THD min Vc THD max Vc THD min Ia THD max Ia THD min Ia THD max Ia THD min Ib THD max Ib THD min Ib THD max Ib THD min Ic THD max Ic THD min Ic THD max Ic THD min Ia K Factor max Ia K Factor min Ia...

Page 40: ...tead of the interval energy consumption the Data Recorder function should be used in the PMC 630E The recorded data is stored in the device s non volatile memory and will not suffer any loss in the ev...

Page 41: ...rm recorder logs can be retrieved via communications by our PecStar iEMS iEEM iPQMS or our free PMC Setup Software for display Figure 4 1 Waveform Recording displayed in PecStar 4 4 6 SOE Log The PMC...

Page 42: ...HD THD THD TEHD TEHD TEHD TOHD TOHD TOHD 2 nd Harmonics 2 nd Harmonics 2 nd Harmonics 31 st Harmonics 31 st Harmonics 31 st Harmonics Harmonics Current THD THD THD THD TEHD TEHD TEHD TEHD TOHD TOHD TO...

Page 43: ...int provides the following setup parameters 1 Transient Enable Disabled Enable 2 Transient Limit 0 05xVLLnominal to 5 00xVLLnominal 3 Transient Trigger 1 2 WR 1 4 6 On board Web Server The PMC 630E s...

Page 44: ...et Gateway the following parameters should be configured via its Front Panel 1 Configure the PMC 630E s IP address Subnet Mask and Gateway Address 2 Make sure that the PMC 630E s RS485 Port s baudrate...

Page 45: ...ion Code 0x14 1 Byte Byte Count 1 Byte Byte Count 1 Byte NxN0 2 Sub Req X Reference Type 0x06 1 Byte Sub Res X Byte Count 1 Byte NxN0 1 Sub Req X File Number 2 Bytes Sub Res X Reference Type 0x06 1 By...

Page 46: ...8 RO kWc 1 Float W 0030 RO kW Float W 0032 RO kvara 1 Float var 0034 RO kvarb 1 Float var 0036 RO kvarc 1 Float var 0038 RO kvar Float var 0040 RO kVAa 1 Float VA 0042 RO kVAb 1 Float VA 0044 RO kVAc...

Page 47: ...or the DI Status register the bit values of B0 to B5 represent the states of DI1 to DI6 respectively with 1 meaning active closed and 0 meaning inactive open 3 For the RO Status register the bit value...

Page 48: ...be reset to zero To determine the latest WFR log location WFR 1 s latest log location Modulo WFR 1 Pointer WFR 1 Depth WFR 2 s latest log location Modulo WFR 2 Pointer WFR 2 Depth 7 The range of the...

Page 49: ...DI2 UINT32 0354 RW Counter 3 DI3 UINT32 0356 RW Counter 4 DI4 UINT32 0358 RW Counter 5 DI5 UINT32 0360 RW Counter 6 DI6 UINT32 Table 5 4 Pulse Counter 5 1 4 Harmonic Measurements The Harmonics data I...

Page 50: ...rmonic UINT16 10000 0484 RO Vc 2 nd Harmonic UINT16 10000 0485 RO Ia 2 nd Harmonic UINT16 10000 0486 RO Ib 2 nd Harmonic UINT16 10000 0487 RO Ic 2 nd Harmonic UINT16 10000 0488 RO I4 Measured 2 nd Har...

Page 51: ...INT32 W 1030 RO kWc Demand INT32 W 1032 RO kW Demand INT32 W 1034 RO kvara Demand INT32 var 1036 RO kvarb Demand INT32 var 1038 RO kvarc Demand INT32 var 1040 RO kvar Demand INT32 var 1042 RO kVAa De...

Page 52: ...INT32 W 1432 RO kW max INT32 W 1434 RO kvara max INT32 var 1436 RO kvarb max INT32 var 1438 RO kvarc max INT32 var 1440 RO kvar max INT32 var 1442 RO kVAa max INT32 VA 1444 RO kVAb max INT32 VA 1446 R...

Page 53: ...00 Hz 1660 RO V Unbalance min INT32 x1000 1662 RO I Unbalance min INT32 x1000 1664 RO Va THD min INT32 x10000 1666 RO Vb THD min INT32 x10000 1668 RO Vc THD min INT32 x10000 1670 RO Ia THD min INT32 x...

Page 54: ...ture x100 V 2006 2011 RO Vb max x100 V 2012 2017 RO Vc max x100 V 2018 2023 RO VLN average max x100 V 2024 2029 RO Vab max x100 V 2030 2035 RO Vbc max x100 V 2036 2041 RO Vca max x100 V 2042 2047 RO V...

Page 55: ...Ib min x1000 A 2360 2365 RO Ic min x1000 A 2366 2371 RO I average min x1000 A 2372 2377 RO I4 min 1 x1000 A 2378 2383 RO kW min W 2384 2389 RO kvar min var 2390 2395 RO kVA min VA 2396 2401 RO P F mi...

Page 56: ...A 2696 2701 RO P F max x1000 2702 2707 RO FREQ max x100 Hz 2708 2713 RO Va THD max x10000 2714 2719 RO Vb THD max x10000 2720 2725 RO Vc THD max x10000 2726 2731 RO Ia THD max x10000 2732 2737 RO Ib T...

Page 57: ...x10000 3032 3037 RO Ib THD min x10000 3038 3043 RO Ic THD min x10000 3044 3049 RO Ia K Factor min x10 3050 3055 RO Ib K Factor min x10 3056 3061 RO Ic K Factor min x10 3062 3067 RO V Unbalance min x1...

Page 58: ...68 0 100 6012 RW Subnet Mask UINT32 E g if the Subnet Mask is 255 255 255 0 write 0xFFFFFF00 to this register Default 255 255 255 0 6014 RW Gateway Address UINT32 E g if the Gateway Address is 192 168...

Page 59: ...UINT16 6047 6050 Reserved 6052 RW Ia Polarity UINT16 0 Normal 1 Reverse 6053 RW Ib Polarity UINT16 6054 RW Ic Polarity UINT16 6055 RW Harmonic Calculation UINT16 0 Fundamental 1 RMS 6056 RW Enable Ene...

Page 60: ...t Note 6400 WO Manual WFR Log 1 Trigger UINT16 Writing 0xFF00 triggers the respective Waveform Recorder 6401 WO Manual WFR Log 2 Trigger UINT16 6402 WO Clear DR 1 Standard UINT16 Writing 0xFF00 to the...

Page 61: ...Parameters 5 3 1 Setpoint Setup Registers Register Property Description Format 6600 6609 RW Setpoint 1 Standard See Section 5 3 2 Setpoint Setup Register Structure 6610 6619 RW Setpoint 2 Standard 66...

Page 62: ...ve Limit is DI Close DI 1 and Inactive Limit is DI Open DI 0 2 For Under Setpoint the Active Limit is DI Open DI 0 and Inactive Limit is DI Close DI 1 10 DI2 11 DI3 12 DI4 13 DI5 14 DI6 15 Reserved 16...

Page 63: ...Standard 7184 7206 RW Data Recorder 9 Standard 7207 7229 RW Data Recorder 10 Standard 7230 7252 RW Data Recorder 11 Standard 7253 7275 RW Data Recorder 12 Standard 7276 7298 RW Data Recorder 13 Standa...

Page 64: ...2 1 to 3456000 seconds Default 900 5 RW Recording Offset 3 UINT16 0 to 43200 seconds 6 RW Number of Parameters 4 UINT16 0 to 16 7 RW Parameter 1 UINT16 0 to 322 8 RW Parameter 2 UINT16 0 to 322 9 RW P...

Page 65: ...vailable for standard data recording If Number of parameters is set to 0 the Data Recorder is disabled 5 Modifying Recording Mode Recording Depth Recording Interval Recording Offset Number of Paramete...

Page 66: ...Energy Log starts to record 3 Record Size Bytes Number of Parameters x 4 8 Energy Log Size Recording Depth x Record Size The Log Size is rounded up to the nearest kB 4 Modifying Recording Depth Recor...

Page 67: ...ize is rounded up to the nearest kB 4 Modifying the Setup Parameters of WFRx will clear the WFRx Log and reset WFRx Pointer will be reset to 0 5 7 SOE Log The SOE Pointer points to the register addres...

Page 68: ...16 1 to 31 Low order Byte Hour 0 to 23 9002 RW High order Byte Minute UINT16 0 to 59 Low order Byte Second 0 to 59 9003 RW Millisecond UINT16 0 to 999 9004 RW UINX Time UINT32 946684800 to 4102444800...

Page 69: ...pen UINT16 Writing 0xFF00 Table 5 25 RO Control 5 10 Meter Information Register Property Description Format Note 9800 9819 RO Meter Model 1 UINT16 9820 RO Firmware Version UINT16 e g 10000 shows the v...

Page 70: ...Table 5 27 ASCII Encoding of PMC 630E 5 11 Data Format 5 11 1 Peak Demand Data Structure Offset Property Description Format Note 0 RO Peak Demand INT32 2 RO High order Byte Year UINT16 0 99 Year 2000...

Page 71: ...rmat Note 0 RO Parameter 1 INT32 2 RO Parameter 2 INT32 RO INT32 2N RO Parameter N N 0 to 5 INT32 2N 1 RO High order Byte Year UINT16 0 99 Year 2000 Low order Byte Month 1 to 12 2N 2 RO High order Byt...

Page 72: ...N 4 RO Ib sample value 1 to N UINT16 x1000 A 5N 5 to 6N 4 RO Ic sample value 1 to N UINT16 x1000 A N of Samples Table 5 32 WFR Data Structure 5 11 6 SOE Log Data Structure Offset Properties Descriptio...

Page 73: ...THD x10000 42 Vb THD x10000 43 Vc THD x10000 44 Va TOHD x10000 45 Vb TOHD x10000 46 Vc TOHD x10000 47 Va TEHD x10000 48 Vb TEHD x10000 49 Vc TEHD x10000 50 Ia THD x10000 51 Ib THD x10000 52 Ic THD x1...

Page 74: ...121 Vc 22 nd Harmonic x10000 122 Va 23 rd Harmonic x10000 123 Vb 23 rd Harmonic x10000 124 Vc 23 rd Harmonic x10000 125 Va 24 th Harmonic x10000 126 Vb 24 th Harmonic x10000 127 Vc 24 th Harmonic x10...

Page 75: ...00 200 Ia 25 th Harmonic x10000 201 Ib 25 th Harmonic x10000 202 Ic 25 th Harmonic x10000 203 Va Demand x100 V 204 Vb Demand x100 V 205 Vc Demand x100 V 206 VLN avg Demand x100 V 207 Vab Demand x100 V...

Page 76: ...er Demand Period x1000 267 P F b max per Demand Period x1000 268 P F c max per Demand Period x1000 269 P F max per Demand Period x1000 270 Freq max per Demand Period x100 Hz 271 U Unbalance max Per De...

Page 77: ...Demand Period VA 304 P F a min per Demand Period x1000 305 P F b min per Demand Period x1000 306 P F c min per Demand Period x1000 307 P F min per Demand Period x1000 308 Freq min Per Demand Period x1...

Page 78: ...oint Active 2 Trigger Value x100 Over VLL Setpoint Active 3 Trigger Value x1000 Over Current Setpoint Active 4 Trigger Value x1000 Over I4 Setpoint Active 5 Trigger Value x100 Over Freq Setpoint Activ...

Page 79: ...Over Current Setpoint Return 49 Return Value x1000 Over I4 Setpoint Return 50 Return Value x100 Over Freq Setpoint Return 51 Return Value Over kW Setpoint Return 52 Return Value Over kvar Setpoint Re...

Page 80: ...Trigger Value x100 Under Freq Setpoint Active 96 Trigger Value Under kW Setpoint Active 97 Trigger Value Under kvar Setpoint Active 98 Trigger Value x1000 Under P F Setpoint Active 99 0 DI1 Open Setp...

Page 81: ...nder VLL Setpoint Return 138 Return Value x1000 Under Current Setpoint Return 139 Return Value x1000 Under I4 Setpoint Return 140 Reserved 141 Return Value Under kW Setpoint Return 142 Return Value Un...

Page 82: ...2 0 Power Supply of CPU Fault 3 0 A D Fault 4 0 NVRAM Fault 5 0 System Parameter Fault 6 0 Calibration Parameter Fault 7 0 Setpoint Parameter Fault 8 0 Data Recorder Parameter Fault 9 0 Waveform Recor...

Page 83: ...og via Communications 21 0 Clear Energy Log via Communications 22 0 Clear Max Min Log of This Month via Communications 23 0 Clear Peak Demand of This Month via Communications 24 0 Clear Peak Demand of...

Page 84: ...6 DIC Type Sampling Debounce Dry contact 24VDC internally wetted 1000Hz 1 1 000ms programmable Relay Outputs DO11 DO12 DO21 DO22 DO31 DO32 Type Loading Form A Mechanical Relay 8A 250VAC 8A 24VDC 5A 30...

Page 85: ...red 0 2 reading 0 05 F S 0 001A I4 Calculated 0 5 F S 0 001A kW kVA IEC 62053 22 Class 0 5S 0 001k kWh kVAh IEC 62053 22 Class 0 5S 0 01kXh kvar kvarh IEC 62053 23 Class 2 0 001k 0 01kvarh P F IEC 620...

Page 86: ...ment of electromagnetic disturbance characteristics of industrial scientific and medical ISM radio frequency equipment EN 55011 2009 CISPR 11 A1 2011 Limits and methods of measurement of radio disturb...

Page 87: ...us Ceiec Electric Technology Headquarters 8 F Westside Building 201 Terra Industrial Tradepark Che Gong Miao Shenzhen Guangdong P R China 518040 Tel 86 755 8341 5187 Fax 86 755 8341 0291 Email suppor...