FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
3
INSTALLATION
ORIGINAL
INSTRUCTION
53
3.1.2 General guidelines for mechanical installation
The following guidelines provide the necessary information to install the system, guaranteeing
minimum clearance for the Metal Detector. Additional indications are also given for THS Systems
intended for installation on final Customers' conveyor belts
For the installation checks you need to be able to switch on the system, understand the signals given
during use and set the applicable operating parameters. These operations are described in the first
part of section
4 – Use of the device
.
3.1.2.1 Controls and Power Supply box
Standard EN 60204-1 specifies that the main switch and the other controls to be used by the operator
must be at a height of between 60 and 180 cm from the floor.
In cases where it is not possible to comply with this specification, additional remote control units shall
be installed at the specified height.