FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
3
INSTALLATION
ORIGINAL
INSTRUCTION
55
3.1.2.2.1 Free-fall
products
S
Metal Detector Probe
P
Stainless steel load-bearing structure
f
Stainless steel moving part
t
Plastic material
Pi
Insulation of the load-bearing structure
(
P
)
see paragraph 3.1.2.3
Si
Fixing and insulation of the Probe (
S
)
see paragraph 3.3.1.2
Fi
Insulation of metal flanges
see paragraph 3.1.2.6
DH
Diameter of the Probe
S
transit tunnel
Df
Respect distance between Probe
S
and any static metal masses
see table below
Dm
Respect distance between Probe
S
and any moving metal masses
see table below
H
Distance between Probe
S
and
support structure
P
H > Df
V
Moving part reference dimension
V = 200x160x2 mm
Installation example for a THS/G21 with free-fall product
THS/G21x THS/G21x-F
Df
0,5 DH
0,4 DH
Static metal masses
Dm
1,5 DH
DH
Small moving metal masses (i.e. piston rod)
Bigger moving metal masses