FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
3
INSTALLATION
ORIGINAL
INSTRUCTION 103
3.6.4 IXC card (available on request)
The IXC card gives the
Detector:
-
A network interface, either
Ethernet or WiFi, with the
following characteristics:
-
Ethernet port speed:
100 Mbps max
-
IP protocol:
Static/DHCP
-
WiFi mode:
Infrastructure (range of
about 10-15 m in open
area)
-
WiFi security:
Open/WPA2
-
A USB interface, to save
or load (from/to an
external USB memory
device, FAT32 formatted,
connected to the USB
port) all data relative to the
products, the Metal
Detector configuration and
occurred events.
-
An internal memory where
the occurred events are
saved (up to 100,000
events).
AM31
: External USB (optional)
Perform the connection to the network through one of the Ethernet ports available. The free port can be used
for the direct connection to a PC or for the cascade connection with another System: in this latter case,
however, the network connection will not be anymore available in case of shutdown of the System where it is
connected.
The
WiFi Dongle
USB adapter is reserved for the system's wireless interface. Its removal determines the
interruption of the functions associated with it.
USB1
RS232
reserved
WiFi Dongle
do not remove
ETH1 or ETH2
Ethernet connection