7
3) To exit from the SPECIAL FUNCTIONS “Fx” menu:
• Press and release once the SPECIAL FUNCTIONS “Fx” Key
(T3) if you are on the FIRST LEVEL MENU.
• Press and release twice the SPECIAL FUNCTIONS “Fx” Ke
(T3) if you are on the SECOND LEVEL MENU.
WARNING:
The functions that can be selected depend on the
welding process activated. For this reason details of each fun-
ction are given on the next pages, along with a description of the
welding processes.
Special Functions Menu (SPC FnC)
PROCESS DEFAULT (dEF)
WARNING:
This operation, if performed, brings about the
partial restoration of all of the modifiable parameters to the
settings already defined in the factory (excluding deletion of
JOBS).
To carry out the reset of the settings / parameters, proceed in the
following manner:
1) Within the SECOND LEVEL MENU rotate the ENCODER - A
(E1) knob until both the displays read
dEF no
(see figure).
E1
2) Rotate the ENCODER - V knob (E2) until the PARAMETERS
DISPLAY - V screen (D2) reads
YES
.
E2
D2
3) Hold the SAVE “MEM” key (T2) down for at least
2
consecu-
tive seconds.
T2
7V
4) At this stage the
partial reset
or
process default
procedure
has been completed successfully (the parameters have been
taken back to the factory values, while any JOBS saved re-
main unaltered).
FACTORY DEFAULT (FAC)
WARNING:
This operation, if performed, brings about the total
restoration of all of the modifiable parameters to the settings
already defined in the factory (including deletion of JOBS).
To carry out the reset of the settings / parameters, proceed in the
following manner:
1) Within the SECOND LEVEL MENU rotate the ENCODER - A
(E1) knob until both the displays read
FAC no
(see figure).
E1
2) Rotate the ENCODER - V knob (E2) until the PARAMETERS
DISPLAY - V screen (D2) reads
YES
.
E2
D2
3) Hold the SAVE “MEM” key (T2) down for at least
2
consecu-
tive seconds.
T2
7V
4) At this stage the
total reset
or
factory default
procedure has
been completed successfully (the parameters have been ta-
ken back to the factory values and any JOBS saved have been
deleted). To confirmation the above, the control panel of the
welder performs a short operation of MACHINE CHECK (all
of the LED stay lit simultaneously so as to verify their actual
operation), the generator itself starts, having memorised the
new settings and is again ready to weld.