![CEA TREO 1800 Synergic MIG-MAG Operator'S Manual Download Page 28](http://html1.mh-extra.com/html/cea/treo-1800-synergic-mig-mag/treo-1800-synergic-mig-mag_operators-manual_2577260028.webp)
6
2) You can access the SECOND LEVEL MENU (except for when
the JOB process is active) only via the
SPECIAL FUNCTIONS
MENU (SPC FnC)
parameter, as follows:
• Within the FIRST LEVEL MENU, rotating the ENCODER
Knob - A (E1) until there appears on both the displays the
SPC FnC
parameter and subsequently keeping pressed
down the SAVE “MEM” Key (T2) for a duration of at least
2
seconds (see figure).
T2
E1
T
2 s
Within the SECOND LEVEL MENU:
• Rotate the ENCODER - A knob (E1) to select the special
function required.
• Rotate the ENCODER - V knob (E2) to edit the setting for
the special function selected.
• It is not possible to begin welding again or to continue wel-
ding.
E1
E2
To go back to the FIRST LEVEL MENU press and release the
SPECIAL FUNCTIONS “Fx” key (T3).
T3
Table 1
ADJUSTABLE FUNCTIONS “Fx”
FUNCTION
DISPLAY
SETTINGS RANGE
WELDING PROCESS
MIG-MAG WELDING MODE
FACTORY
RANGE
MIG
MAG
SYN
MIG
MAG
MAN
TIG
MMA
2T
4T
CRA
2T
CRA
4T
SPOT
2T
STITCH
2T
FIRST LEVEL MENU
MIG-MAG process
PRE GAS
PrG
0.1s
(0.0 ÷ 2.0)s
●
●
●
●
●
●
●
●
STARTING SPEED
Sts
0
-30 ÷ +30
●
●
●
●
●
●
●
●
HOT START
Hot
0
-30 ÷ +30
●
●
●
●
●
●
●
●
CRATER
INITIAL
CRATER
CRATER START CURRENT
CSC
20%
(-50 ÷ +100)%
●
●
●
CRATER START SPEED
CSS
5.0m/min
(0.6 ÷ MAX)m/min
●
●
●
CRATER START VOLTAGE
CSu
15.0V
(min ÷ MAX)V
●
●
●
CRATER START TIME
CSt
1.0s
(0.0 ÷ 5.0)s
●
●
●
SLOPE
SLo
1.0s
(0.0 ÷ 8.0)s
●
●
●
●
FINAL
CRATER
CRATER END CURRENT
CEC
-30
(-99 ÷ +50)%
●
●
●
CRATER END SPEED
CES
5.0m/min
(0.6 ÷ MAX)m/min
●
●
●
CRATER END VOLTAGE
CEu
15.0V
(min ÷ MAX)V
●
●
●
CRATER END TIME
CEt
0.0s
(0.0 ÷ 5.0)s
●
●
●
SPOT WELD TIME
SPt
3.0s
(0.1 ÷ 20.0)s
●
●
●
STITCH WELD
STITCH WELD TIME
SAt
1.0s
(0.1 ÷ 8.0)s
●
●
●
STITCH WELD PAUSE
Srt
1.0s
(0.1 ÷ 8.0)s
●
●
●
BURN BACK
bub
0
-30 ÷ +30
●
●
●
●
●
●
●
●
POST GAS
PoG
1.0s
(0.0 ÷ 10.0)s
●
●
●
●
●
●
●
●
TIG process
UP SLOPE
uP
0.0s
(0.0 ÷ 5.0)s
●
DOWN SLOPE
don
2.0s
(0.0 ÷ 8.0)s
●
SWS VOLTAGE LIMIT
SuL
0
-30 ÷ +30
●
MMA process
HOT START
Hot
50
0 ÷ 100
●
ARC FORCE
Arc
50
0 ÷ 100
●
SECOND LEVEL MENU
SPECIAL FUNCTIONS MENÙ
SPC FnC
PROCESS DEFAULT
dEF
no
no - YES
●
●
●
●
●
●
●
●
●
●
FACTORY DEFAULT
FAC
no
no - YES
●
●
●
●
●
●
●
●
●
●
SAFETY CALIBRATION CODE
SCC
7
0 ÷ 100
●
●
●
●
●
●
●
●
MOTOR CALIBRATION
CAL
●
●
●
●
●
●
●
●
Summary of Contents for TREO 1800 Synergic MIG-MAG
Page 12: ...12 Electro topographical diagram 2101AB10...
Page 14: ......
Page 22: ......
Page 42: ......