At port TP2 backup-systems or a webcam can be connected via TP-cable. The connected device can be
powered by the AirLaser IP1000plus via PoE. The AirLaser supports the IEEE802.3af PoE standard and a
proprietary forced mode with increased power.
3.3
Mounting and adjustment
Connect the holder at the foreseen place with stainless and qualified screws. Be sure
that the ground is stable and vibration-free.
Set up the swivel-head and fix it.
Adjust the swivel head horizontal.
Fix
only one
screw for the vertical adjustment (red arrow).
Set up the terminal so that all 4 holes are over the blue arrows. Make sure that
there is a plastic disk at all fittings between AirLaser and the swivel head.
Use only the 6 x 18 screws together with a spring-lock-washer.
Now tighten the second screw for vertical alignment.
Attention:
For securing the screws use necessarily a spring ring.
Make sure that a plastic disk is present on all fittings between AirLaser and swivel head.
Do not use longer screws, otherwise damage could be caused to the optics of the AirLaser!
Please note the installation instructions for the swivel head.
8