7.5 Time + Date
Here is time and date configuration for AirLaser management possible. If the NTP service is enabled, NTP
time will be used. Otherwise, the manual configured time is used. The time is needed for the time stamps in
the log file and for the creation of the History. If you change date or time of the AirLaser, you should delete
afterwards the History, so that it does not come to an inconsistency in the data record of the History. The
change between daylight saving time and normal time is made by the AirLaser IP1000plus automatically on
the basis of the time zone, if "auto summer time" is activated.
Type
Default
Description
System Time
Date
not affected by a default reset current local time and date
Time Zone
Integer
GMT + 1 (Berlin, Rome, Paris) time zone of location of installation
Auto Summer
Time
Boolean
Enabled
enables/disables the automatic daylight
saving time
NTP Service
Boolean
Disabled
enables/disables the ntp-service
NTP-Server
String[64]
domain name or IP-address of ntp server
NTP-Port
Integer
123
port number of ntp service