AirLaser IP1000plus with integrated backup
Configure port TP2 as Backup Path, if you connect the integrated backup to it.
Port
Logic
Application
FSO
Default Path
free space path
TP1
Local Port
connection to your network and power supply
TP2
Backup Path
integrated backup
AirLaser IP1000plus as Backup for a dedicated line
If you should use the AirLaser IP1000plus as Backup to a dedicated line, then the change-over in the event
of an error can be made by the AirLaser IP1000plus. You can make the connection to your network for
example over TP1 and attach the dedicated line (glass fibre) to F1.
Port
Logic
Application
FSO
Backup Path
free space path
TP1
Local Port
connection to your network and power supply
TP2
Disabled
not used
F1
Default Path
dedicated line
AirLaser IP1000plus with Webcam
If you would like to supervise your fso-link with an IP camera, then you can attach this simply to the TP2. The
port powers your camera, if this is IEEE802.3af compatible. Here our recommended settings.
Port
Logic
Application
FSO
Default Path
free space path
TP1
Local Port
connection to your network
TP2
Local Port
IP camera
AirLaser IP1000plus with outband management
If the management of AirLasers shall not be accessible via the local port, you can specify a separate port on
which you want to address the management.
Port
Logic
Application
FSO
Default Path
free space path
TP1
Local Port
connection to your network
TP2
Local Port
IP camera
23