5
Terminal unit
To operate the AirLaser IP1000plus and possibly a backup installed a terminal unit is required for each
location. The terminal unit supplies both the AirLaser IP1000plus, and the backup system on the TP data
cable with power and protects at the same time through the built-in surge protection type 2 the network
against surges, which can occur for example during thunderstorms.
5.1 Installation
The terminal unit is only suitable for indoor use. The mounting location should be near the location of the
radio equipment, dry and frost free. An ambient temperature of 55 ° C in the variant 1 and 40°C in variant 2
must not be exceeded.
The terminal unit can optionally be screwed on a flat surface, or it can be installed in 19" cabinets with an
optional front panel. The front panel has a height of 2U.
The electrical connection of the terminal unit depending on the version is made to one or two electrical
outlets and a separate potential equalization. The electrical connection must only be carried out by
appropriately trained personnel!
5.2 Model 1 - Basic Device
The standard version of the terminal unit consists of a mounting plate, on which the switching power supply
for the AirLaser IP1000plus and the backup is mounted. Under the metal cover is the PoE injector with
integrated surge protection.
At the rear TP port of the PoE injector the AirLaser IP1000plus is plugged, the network port on the front.
11
Terminal unit for the AirLaser IP1000plus