3.
SLOW CLOSE DISTANCE (%)
The slow close distance sets the door deceleration start position 0 ~ 100% (25mm ~
355mm). The closing distance is adjustable using the potentiometer on the front of
the controller. The position is set at 50% when delivered.
4.
OPENING DIRECTION
The slide switch sets the door opening direction as viewed from componentry
access side of the door operator. Set the direction before turning ON the power
supply for safety. The direction cannot change if the power is already ON.
- Left Hand: Move slider to Position
L
(Pocket is on Left, Opening side on Right)
- Right Hand: Move slider to Position
R
(Pocket is on Right, Opening side on Left)
- Bi-Parting: Set as left hand as standard - Position
L
If the power is turned OFF again, wait for about 5 seconds before turning ON again
DOOR HANDING
5.
TEST BUTTON
The test button allows you to open and close the door without an activation switch.
This allows controller functionality to be checked while accessing the controller
without an activation switch.
This button also resets the digital counter for door opening and closing. See
document section -
HOW TO RESET THE CYCLE COUNT
6.
MONITOR (MAX. 9,999,999)
This digital counter shows the number of door opening and closing sequences or
cycles the controller has completed. This counter reaches a maximum value of
9,999,999. The cycle number is memorized even if the power supply is turned OFF.
The cycle count is useful when the auto unit is undergoing repairs or setting
maintenance sequels.
This number can be reset, see document section -
HOW TO RESET THE CYCLE
COUNT