6
•
OPENING WIDTH ADJUSTMENT
Connect wire of a variable resistor of up to 1K
Ω
for door opening width adjust to be
connected to this INPUT. It adjusts the door opening width. To widen, turn it
clockwise.
- Terminal E and F on advanced input Plug.
5.
MICROCOMPUTER CONTROL BOX HP-17H2
ADJUSTMENT OF HP-17H2
1.
HOLD OPEN TIMER (SEC)
The hold open timer sets the duration the door stays in the pocket after opening
before the door starts to close. This only applies when the activate switch (sensor
etc.) turns OFF, otherwise the door will stay open. The hold open time is adjustable
from 0 to 10 seconds on the front of the controller.
2.
CLOSING SPEED (mm/S)
The speed the door closes is adjustable on the controller through the potentiometer
on the front. The closing speed can be set to 100~500mm/sec. The speed is set at
250mm/sec when delivered.
Recommended closing speed
Over speed range (caution required)
Min. speed
Upper limit speed
Approx 300~350
Max. speed
Approx
100mm/sec.
Approx
250mm/sec
mm/sec.
Approx
500mm/sec