![Cavity Sliders Solic CS005 Operation Manual Download Page 12](http://html1.mh-extra.com/html/cavity-sliders/solic-cs005/solic-cs005_operation-manual_2574985012.webp)
12
DIP SWITCH 4: FUNCTION -
Dependent on selection of dip switch 5.
If dip switch 5 is ON/UP (Auto Door Mode)
PUSH TO OPEN
When the door is fully closed. If door is opened 2cm by hand, the door can be set to
self-open or stay closed.
State
Setting
ON (UP)
Close –
(Setting for optional lock)
The door remains closed even if
it is opened 2 cm hand
OFF (DOWN)
Open – the door completes an open/close cycle if it is opened 2cm
by hand.
If dip switch 5 is OFF/DOWN (Closer Mode)
PUSH TO CLOSE
If dip switch 4 is turned on the door will continuously push against the closing jamb.
While in closer mode regardless of the setting of dip switch 4, when the door is opened
2cm by hand the door completes an open/close cycle
State
Setting
ON (UP)
With pressing (continuous push to close)
OFF(DOWN)
No pressing
DIP SWITCH 5: DOOR FUNCTION
Selection of whether the microcontroller acts as an automatic door operator or a door
closer.
State
Setting
ON (UP)
AUTODOOR: Automatic door operator
OFF(DOWN)
CLOSER: Door closer
DIP SWITCH 6: DIRECTION OF FIRST MOVE
The direction of the initial door movement is selectable when the power is turned ON.
State
Setting
ON (UP)
OPEN - The door starts opening when the power is turned ON.
OFF (DOWN)
CLOSE: The door starts closing when the power is turned ON.
DIP SWITCH 7: POWER FAILURE MODE OF LOCK
This switch is set for the optional door lock. It sets the type of door lock the
microcontroller is required to operate. Either the power failure safe type “unlocked” or
power failure secure type “locked”.
State
Setting
ON (UP)
UNLOCK – Set as standard for CS motor lock LK001.
OFF (DOWN)
LOCK – Available upon request.