4.

 

TRANSFORMER INPUT CONNECTIONS (Input • Output) 

 

   

 

 

 

1.

 

Activation Switch 

(2 supplied with unit)

 

Lead output wires of activation device such as sensor switch, button etc., to be 
connected to this input plug in track. Two 5m 4-core wires will be supplied with the 
correct terminal connection to plug into the input. 
-

 

The door opens and closes when signalled from the activation device. 

 

2.

 

Lock Switch – 

(If optional lock is attached)

 

Lead output wires of activation device such as sensor switch, button etc., to be 
connected to this input plug in track. A single 5m 2-core wire will be supplied with 
correct terminal connection to plug into the input. 
-

 

When the lock switch is turned ON the lock will engage 

-

 

Lock will automatically disable, and the door opens when the activation switch is 
on. Lock will automatically re-engage when closed. 

-

 

When the Lock switch is turned OFF the door can be pushed open. 

 

3.

 

Safety Beams – 

(Optional upon order)

 

Safety beams can be applied to the auto door unit upon request. These will be 
fitted/wired in position on the cavity and auto head prior to leaving the factory. 
-

 

Only during a closing movement, the door will open and stay open while the 
beam lines are broken (When something is in/crossing the walkway). 

-

 

The beams are only active while the door is open/closing. When the door is fully 
closed, breaking the beams will not open the door. 

 

4.

 

Advanced Features – (

Optional upon order)

 

The following advanced features can be applied to the auto door unit upon request. 
The wire loom - L003 will need to be ordered from CS FOR DOORS to be able to 
wire/connect the activation devices to the controller:  

 

OUTPUT 24VAC 0.5A 
24V AC is supplied from this output for an auxiliary device requiring power. 
-   Terminal A and H on advanced input plug 

(A is line, H is neutral)

 

 

 

BREAKAWAY 
When breakaway is active, power is cut to the motor and the door is operated as a 
manual slider. Power is still connected to the controller and motor acts as a soft-
open/close device to avoid pinching fingers when operating the door by hand. 
When the switch is turned off the door resumes normal operation. 
-   Connect activation device to Terminal C and G on advanced input plug. 

 

 

REVERSIBLE PART

SEE INSTRUCTIONS

Instructions & Support: www.csfordoors.co.nz/Technical/AutoCav-Support

BELT TENSION:

 Do not over-tighten. 

Turn bolt 

+

 direction until belt is 

parallel/straight between pulleys. 
Add extra 3 full turns for correct 
tension.

BELT TENSION:

 Do not over-tighten. 

Turn bolt 

+

 direction until belt is 

parallel/straight between pulleys. 
Add extra 3 full turns for correct 
tension.

TO ATTACH BELT

• Attach belt to belt clamp bracket
• Place over motor pulley
• Place over tensioner pulley
• Tighten belt to correct tension

TO REMOVE BELT 

- follow steps above in reverse

Bend up 
locking 
tab

TENSION

Tension 
Bolt

LOOSEN

Tensioner

Pulley 

Top

Screws

(3)

Belt

Front

Screws

(2)

Belt Clamp

Bracket

SW2

_

BN

BU

Receiver

MOTOR

M

Lock SW1

BN

BU

Emitter

LockSW2

DOOR 

CONTROLLER

PULLY

LOCK

SAFETY BEAM
CONTROLLER

Lo

ck

M

od

e

4*

0.

5m

m

2

15*0.5mm2

Activation

Activation

SW 1

H

ol

d

O

pe

n

Opening Width
Adjust

O

pe

ni

ng

Pr

io

rit

y

INPUTS

8*0.5 mm2

3*1mm2

11*0.5mm2

2*0.5mm2

• Slides up and down to adjust height 

of belt or to separate from drive bar 

• Loosen front screws to adjust

Remove top 
screws on belt 
clamp bracket to 
disconnect belt

Drive Bar

Height Adjusting Screws (2)

Remove these screws only if you 

need to take door out of pocket.

F = Front.

 Must face you 

(visible) when installing

POWER OUTLET

120/230VAC-3A

Connector Bracket

1

RED 

+

 

24VAC

2

BLACK 

3

WHITE

SWITCH

4

BLUE

5

RED

LOCK

6

BLACK

1 3
2 4

1 3
2 4

A B C D E
H G G G F

5 6

5 6

ACTIVATION 

SWITCH

ACTIVATION 

SWITCH

ACTIVATION SWITCH

LOCK SWITCH

LOCK SWITCH

LOCK SWITCH

ACCESS

PANEL SIDE

ADVANCED 

FEATURES SOCKET 

(See Separate Instructions)

OTHER

SIDE

M005

M007

Summary of Contents for Solic CS005

Page 1: ...ON MANUAL AUTOMATIC SLIDING DOOR OPERATOR Microcomputer Control Type MODEL CS005 Motor M005 Hypoid gear type Before using this door operator you should first thoroughly read this manual and keep for future reference ...

Page 2: ...imer Door closing speed Slow close distance Direction of door opening 4 Test button switch The test button switch White for door opening and closing is provided on the microcomputer control box The hold timer door opening and closing speed are easily checked with this switch 5 Various functions There are a variety of extra functions that are available on the microcomputer that are not supplied for...

Page 3: ...e speed 20mm sec Speed is fixed after slowing down Brake position Automatically set according to door weight Slow speed distance Position 0 55mm from close where door speed starts to slow Position is adjustable on controller Hold time Time door is held open Adjustable between 0 10sec on controller Door opening width Adjustable to 10 100 as an extra function CS supply as 100 adjustability is additi...

Page 4: ...4 3 WIRING 1 Example wiring Optional parts are marked with ...

Page 5: ...en the door 4 Advanced Features Optional upon order The following advanced features can be applied to the auto door unit upon request The wire loom L003 will need to be ordered from CS FOR DOORS to be able to wire connect the activation devices to the controller OUTPUT 24VAC 0 5A 24V AC is supplied from this output for an auxiliary device requiring power Terminal A and H on advanced input plug A i...

Page 6: ...ng before the door starts to close This only applies when the activate switch sensor etc turns OFF otherwise the door will stay open The hold open time is adjustable from 0 to 10 seconds on the front of the controller 2 CLOSING SPEED mm S The speed the door closes is adjustable on the controller through the potentiometer on the front The closing speed can be set to 100 500mm sec The speed is set a...

Page 7: ...andard Position L If the power is turned OFF again wait for about 5 seconds before turning ON again DOOR HANDING 5 TEST BUTTON The test button allows you to open and close the door without an activation switch This allows controller functionality to be checked while accessing the controller without an activation switch This button also resets the digital counter for door opening and closing See do...

Page 8: ...r M005 9 4PIN FEMALE CONNECTION Connection point for the 4pin male connector plug from the optional motor lock LK01 10 DIP SWITCH Adjustable dip switches on top of controller See document section DIP SWITCH FUNCTIONS for more details 11 ACCESSORY SCREWDRIVER All adjustments of hold open timer closing speed slow close distance opening direction are done using this screwdriver Adjustments using othe...

Page 9: ...s learning the open and closed positions of the door 3 Adjusting the settings for hold open timer closing speed and slow close distance Setting information for opening closing times when door is fully closed are displayed on the LED monitor When adjusting the hold time 0 10sec HLd Hold time is variable every 0 5 sec between 0 to 10 seconds on adjustment screw pot 10 500 100 10 500 100 0 10 100 500...

Page 10: ...ollowing information During opening Opening speed setting 500mm s Adjustable on dip switch Braking on opening Second distance setting 60 When fully closing When opened by activation device Will count down in 0 5 sec increments from present setting 4 sec in image example During closing Closing speed setting 200mm s Braking on closing Second distance setting 60 Displays the number of completed open ...

Page 11: ...ode 200mm sec DIP SWITCH 2 OBSTACLE DETECTION Setting for adjusting the sensitivity of obstacle detection which re opens the door when meeting a person or object The sensitivity for obstacle detection while the door is moving at a set speed can be adjusted to the following State Setting ON UP STANDARD If the set speed is decreased by more than 75 for 0 5 sec the door re opens In closer mode decrea...

Page 12: ...e State Setting ON UP With pressing continuous push to close OFF DOWN No pressing DIP SWITCH 5 DOOR FUNCTION Selection of whether the microcontroller acts as an automatic door operator or a door closer State Setting ON UP AUTODOOR Automatic door operator OFF DOWN CLOSER Door closer DIP SWITCH 6 DIRECTION OF FIRST MOVE The direction of the initial door movement is selectable when the power is turne...

Page 13: ... photo of your setting before attempting to reset the cycle count Remember to remove the power from the controller when adjusting dip switch settings HOW TO RESET THE CYCLE COUNT Turn DIP SWITCH ON UP if the digital counter is to be reset Hold Test Button for 3 seconds Cycle count will reset Door will start a new learning sequence to find open and closed positions If dip switch 6 is OFF Down when ...

Page 14: ...matically locks when the door is in fully closed position The lock is unlocked and the door opens and closes when the activate switch is turned ON 3 Motor Mounts Aluminium casting with rubber inserts fits the motor to the track and allows easy removal of the motor for maintenance Motor removal once belt is removed from motor pulley Disconnect motor and lock connectors from controller Slide motor i...

Page 15: ...egarding screws and wires 5 Move door to the centre of the opening ready to connect the power 2 Initial movement at power ON 1 When power is turned ON the red LED display shows door opening and closing times 2 The door moves according to dip switch 6 3 During the initial movement When activation devices are off The door when fully open starts closing after the pre set hold open period When closed ...

Page 16: ...seconds and reconnect power Motor connector is missing Wire for motor sensor is broken Motor is out of order Motor sensor U is abnormal Motor sensor U has not changed for more than 5 sec during motor operation Remove power Wait 5 seconds and reconnect power Motor connector is missing Motor wire is broken Motor is out of order Motor shaft is locked Normally it does not occur Motor sensor V is abnor...

Reviews: